To ensure the correct and safe operation of the Comfort insert, when building the fireplace it is
necessary to respect the clearances between the insert and the inner walls of the fireplace.
Considering the measurements given in the technical specifications, you need to account for at
least 50 mm of air space in the upper part and on the two sides.
NB:
The exhaust outlet pipe must always be at a minimum distance of 5 cm from inflammable
parts.
Warm convection air
It is necessary provide an outlet for the
heat accumulated in the facing
to
prevent excessive
overheating of the
insert.
Forced ventilation
The blower conveys the heat produced in
the insert into the room.
Air intake from the room
To enable air circulation, it is necessary
to have an air intake point, preferably at
the lower part of the structure, for better
convection. The air must be drawn from
the room where the stove is installed.
5 cm