background image

ENGLISH

no

iGniTion

BlaCK oUT

No power during the ignition phase.

Turn the stove off using key 1 and repeat the procedure described in the 

"IGNITION" chapter.

Other reset operations should be performed by an authorised technician.

no FlaMe 

The pellet hopper is empty.

No pellet feed.

The gearmotor does not feed pellets.

Check for the presence of pellets in the hopper.

Check bulb thermostats (see chapter on Resetting) 

Adjust the pellet flow (see “Pellet feed adjustment”).     

DepR alaRM 

The door is not closed correctly.

The ash drawer is not closed correctly.

The combustion chamber is dirty.

The fumes exhaust pipe is blocked/dirty

Check hermetic door closure.

Check hermetic closure of the ash drawer.

Check cleanliness of the fumes pipe and the combustion chamber.

H2o oVeRTeMp

Air in the system

Inadequate circulation

Possible air in the system; bleed the system. Lack of adequate circulation. 

Lack of or inadequate safety zone.

The water in the stove has exceeded 95°C. Possible pump anomaly.

If the problem persists, restore operations must be performed by an 

authorised technician.

H2o pRoBe

H2O probe fault

Contact after-sales centre

Min H2o pRessURe 

alaRM    

The system pressure read by the pressure switch 

is too low. 

Possible air in the system; bleed the system. Possible lack of water or leaks 

due to anomalies in some system component.

If the problem persists, contact the service centre.

MaX H2o pRessURe 

alaRM   

The pressure of the water has exceeded the max 

threshold

Possible air in the system; bleed the system. Check that the expansion 

vessels are not damaged or under-dimensioned Check that the cold system 

is loaded at the correct pressure

If the problem persists, contact the service centre.

 aUGeR ConTRol 

alaRM

Abnormal pellet feeding. 

Contact after-sales centre

**

aUGeR BloCKeD

Abnormal operation of pellet motor.

Contact after-sales centre

**TRapDooR BloCKeD

The automatic cleaning of the burn pot is 
blocked. 

Burn pot dirty/clogged

The door is not closed correctly.

Check that the door closes correctly. Check that the burn pot is clear and 

clean. The automatic cleaning of the burn pot is blocked.

If the problem persists, contact the service centre.

**MaX eleCTRiCal 

CURRenT

The automatic cleaning of the burn pot is 
blocked. 

Burn pot dirty/clogged

The door is not closed correctly.

Check that the door closes correctly.

Check that the burn pot is clear and clean.

The automatic cleaning of the burn pot is blocked.

If the problem persists, contact the service centre.

*DHW pRoBe

Fault in DHW TANK probe. 

Contact after-sales centre

*BUFFeR TanK pRoBe

Fault in BUFFER TANK probe.

Contact after-sales centre

pWM inTeRFaCe 

alaRM

IPWM output interface damaged, in short 

circuit or not connected

Contact after-sales centre

HoT pWM alaRM

The pump is operating but not with good 
performance. Undervoltage 160-194v.
Pump in circuit breaker protection mode.

Contact after-sales centre

sToppeD pWM alaRM

The pump has stopped but is still operational.

Undervoltage < 160v. Overvoltage.

Unexpected external flow.

Contact after-sales centre

sToppeD 2 pWM 

alaRM

The pump has stopped but is still operational.

Problem in a component different to the pump. 

Debris in installation.

Positioning in high temperature.

Contact after-sales centre

BloCKeD pWM alaRM

The pump has stopped permanently

Pump blocked. Electronic module damaged

Contact after-sales centre

FloW pWM alaRM

Pump blocked.
Liquid with high density.
Pipe obstructed.

Contact after-sales centre

**FaUlT DelTa-p

Digital pressure switch faulty or disconnected.

Contact after-sales centre

* if there is an additional system data sheet

** on models with this function.

34

Summary of Contents for GUENDA IDRO

Page 1: ...MADE IN ITALY design production GUENDA IDRO 004280684 rev 000 ENGLISH UK THERMO PRODUCTS USER MANUAL...

Page 2: ...2 ENGLISH APPLY TECHNICAL DATA LABEL...

Page 3: ...thermostat operation with STAND BY active 22 Additional thermostat operation with STAND BY deactivated 22 ADDITIONAL THERMOSTAT INSTALLATION 22 VENTILATION 23 EASY SETUP 23 CHRONO 24 ENABLING DISABLIN...

Page 4: ...ance has been installed as well as the instructions contained in this manual The use of the appliance must comply with all local regional national and European regulations The Manufacturer cannot be h...

Page 5: ...IF IT IS DISCONNECTED FROMTHE MAINS It is advised to position the power supply cable so that it does not come into contact with hot parts ofthe appliance The power supply plug must be accessible afte...

Page 6: ...clean the majolicas it is recommended to use a soft dry cloth If a detergent or liquid is used the latter could penetrate inside the crackles highlighting them SINCE THE PRODUCT CAN TURN ON AUTOMATICA...

Page 7: ...mestichotwaterproductionandinadjacentandcommunicating rooms 3 where the depression measured in situ between the external and internal environment is greater than 4 Pa N B Watertight appliances can als...

Page 8: ...always be insulated The smoke ducts must have at least one airtight inlet for flue gas sampling All the sections of the flue gas duct must be accessible to inspection Inspection openings must be prov...

Page 9: ...houses because it does not take air in from within the house combustion air To ensure the stove remains hermetically sealed the connection pipe for the combustion air must be directly connected to th...

Page 10: ...and inspection of correct functioning must be carried out perfectly in full compliance with Standards in force national regional and municipal as well as these instructions For Italy installation mus...

Page 11: ...This is to prevent unexpected power increases The flue fitting can be mounted between the boiler and the flue only after this inspection An inspection of the connections with pre existing flues is re...

Page 12: ...safety drain T2 Boiler flow output T3 Boiler return input Combustive air input Room air outlet Pellet hopper Heat exchanger scrapers Door handle Fumes exhaust Not used fuse Power supply 230v On Off He...

Page 13: ...veying motor and therefore operation of the heat generator The system must be bled several times to eliminate the air and loaded when the pressure is too low It is not an anomaly but normal phenomenon...

Page 14: ...ion means that you have 60 to close the hatch door and the pellet lid If this is not the case during ignition the stove will go to DEPRESSION ALARM mode while during normal operation the stove will go...

Page 15: ...LITY PELLETS OR ANY OTHER MATERIAL DAMAGES THE FUNCTIONS OF THE GENERATOR AND CAN VOID THE WARRANTY AND THE ANNEXED RESPONSIBILITY OF THE MANUFACTURER Pellet tank During the operation of the stove the...

Page 16: ...On off stove hold for 3 seconds 9 Degrees Celsius Fahrenheit 4 Set power 10 Press the button once to enable or disable the chrono 5 Set switch off delay The button allows to set the switch off delay F...

Page 17: ...Handle the remote control with care When it is not being used place it on the special base supplied The remote control must not be left in a place where it is exposed to direct sunlight or near a sour...

Page 18: ...external additional thermostat Closed contact the contact of the external additional thermostat is closed Open contact the contact of the external additional thermostat is open WI FI BT STBY OK ON STA...

Page 19: ...ed to be connected to a hydraulic system it must be complete and fully functional and in compliance with the instructions given in the product manual and with the relevant regulations in force The pel...

Page 20: ...and confirm by pressing key 6 Select the language using keys 4 or 5 Press key 6 to confirm and key 1 to scroll back through the menus until the initial page DEGREES This menu allows you to set the un...

Page 21: ...s of the room temperature probe integrated in the product see the chapter VENTILATION on the following pages BLOW During the working phase the stove has an internal timer which after a pre set period...

Page 22: ...the stove and relative factory setting restrictions If the stove is in H OFF water temperature reached any additional contact or thermostat request will be ignored Additional thermostat operation with...

Page 23: ...e keys 4 5 to set the range Press key 6 to confirm and key 1 to scroll back through the menus until the initial page N B IF THESE ADJUSTMENTS DO NOT SOLVE THE PROBLEM OF PELLET DEPOSITS IN THE BURN PO...

Page 24: ...s and confirm by pressing key 6 Confirm ENABLING by pressing 6 Use keys 4 5 to enable ON or disable OFF Press key 6 to confirm and key 1 to scroll back through the menus until the initial page J If we...

Page 25: ...t 3 1 02 00 23 00 08 00 16 30 t 72 68 2 1 25 ENGLISH Time slot 1 Start 02 00 Stop 23 00 Power 3 SET H2O 72 C Time slot 2 Start 08 00 Stop 16 30 Power 1 SET H2O 68 C Stove operation TIME SLOT SET POWE...

Page 26: ...ressing key 3 until STAND BY appears and confirm by pressing key 6 Use keys 4 5 to enable ON disable OFF Press 1 several times to confirm and exit the menu FIRST LOAD This function allows the auger to...

Page 27: ...key 6 Use keys 4 5 to enable ON disable OFF Press key 1 several times to confirm and exit the menu EASY CONTROL The function allows for two values to be set OFF disabled factory default ON enabled Act...

Page 28: ...pressed the message KEYS LOCKED will appear To lock the keypad press keys 1 and 5 simultaneously until the following message appears KEYS LOCKED To unlock the keypad press keys 1 and 5 simultaneously...

Page 29: ...e the warranty CLEANING THE CERAMIC GLASS Never use abrasive or chemically aggressive detergents for cleaning The ceramic glass must be cleaned when the glass is completely cold To clean the ceramic g...

Page 30: ...ng it at the back A Clean the combustion chamber and the bottom of the burn pot completely using a suitable vacuum cleaner Refit the ash conveyor by performing the same operation in reverse Always mak...

Page 31: ...s to be vacuumed and cleaned If there are horizontal sections the residue must be removed to prevent it from obstructing the flow of fumes SHUT DOWN END OF SEASON At the end of each season before turn...

Page 32: ...and door replace and apply silicone where indicated C Combustion chamber and heat exchanger full cleaning including ignition plug pipe D Hopper complete emptying and cleaning E Check air intake pipe a...

Page 33: ...only if the generator has been in an OFF state for at least 96 hours the pump is activated for the time pre set by the manufacturer in order to prevent it from blocking AUTO BLOW The automatic blow is...

Page 34: ...ER CONTROL ALARM Abnormal pellet feeding Contact after sales centre AUGER BLOCKED Abnormal operation of pellet motor Contact after sales centre TRAPDOOR BLOCKED The automatic cleaning of the burn pot...

Page 35: ...kindly asked to separate this equipment and or batteries or accumulators included from other types of waste and to arrange for disposal by the municipal waste service It is possible to ask your local...

Page 36: ...0445 865911 39 0445 865912 info extraflame it www lanordica extraflame com TO FIND THE SERVICE CENTRE NEAREST TO YOU CONTACT YOUR DEALER OR CONSULT THE SITE WWW LANORDICA EXTRAFLAME COM The manufactu...

Reviews: