ENGLISH
IGnItIon
Once the points listed previously have been checked, press key 1 for three seconds to ignite the stove. 15 minutes are available for the ignition
phase. after ignition and having reached the control temperature, the stove interrupts the ignition phase and switches to sTarTiNg.
PreParatIon
During the preparation phase, the stove stabilises combustion, increasing it progressively, then switches to wOrK.
work
During the work phase, the stove reaches the set power set; see following item.
set Power
set the operating power from 1 to 5 (using keys 2 and 3).
Power 1 = minimum level - Power 5 = maximum level.
set H2o
set the boiler temperature from 65 to 80°C (using keys 4 and 5).
PumP oPeratIon
The pump activates water circulation when the t° of the water inside the stove reaches approx. 60°C. as the pump always functions above 60°,
it is recommended to keep a heating area open at all times to allow for uniform operation, preventing blocks due to overheating. Normally
this area is defined as the “safety zone”.
set tHermostat
it is possible to activate/deactivate front ventilation and check the room temperature by means of the room temperature probe (integrated in
the product - see the chapter "VeNTiLaTiON" on the following pages).
Blow
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it lowers the stove power level and increases the flue gas exhaust motor for a programmed period of time.
when the cleaning phase is finished, the stove will re-start automatically and continue the working phase, returning to the selected power
level.
modulatIon and H-oFF
as the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. if the
temperature increases beyond the set point, it will automatically switch off indicating H-OFF
,
and will automatically go back on when the
temperature drops below the set point.
swItCH-oFF
Press key 1 for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-off phase, blocking the supply of pellets.
the flue gas exhaust motor and the hot air flow motor will remain on until the stove temperature has dropped below the default
parameters.
reIGnItIon
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satisfied.
oPeratIon and loGIC