1.
UK – Product information
The
exodraft
Chimney Fan type RSHG is used as part of the fail-safe flue system for open flued gas
appliances, such as stoves and domestic boliers. The RSHG gives a horisontal discharge of the flue
gases. Max. 200 °C
All installations must be carried out by competent personnel
inaccordance with national laws and regulations
Warning!
Avoid chimney fires – ensure that the chimney has been swept
before mounting the fan.
The chimney fan must always be operating when the fireplace is
in use.
Please always read the installation instructions for the
exodraft
control unit, before installation of the chimney fan.
1.1
Construction and design
Construction
The body and casing are manufactured in cast aluminium, fitted with a stainless steel vane and
non-moving airpres-sure sensors linked to a pressure differential switch (PDS), ensuring correct
airflow when the fire is used. The chimney fan can be opened for service and cleaning purposes.
Main parts
The RSHG has the following main components
a
Motor housing
b
Bottom section
c
Motor
d
Cooling plates
e
Vane
f
Safety hinge
g
Safety net
h
Armoured motor cable
i
Mineral wool mat
j
Safety wire with bolt and rawlplug
k
Location brackets, bolts and nuts
l
Pressure differential switch
m
Non-moving airpressure sensors
3000126-RSHG-UK-DE 20200204
UK •
3
Summary of Contents for RSHG
Page 16: ...3000126 RSHG UK DE 300816...