background image

Installation and Maintenance Manual

IAQ Series 

FADB-04007-6--A
FADB-05011-6--A
FADB-06015-6--A

6720220345   Revised 07-12

Fresh Air Damper System 

Summary of Contents for FADB-04007-6--A

Page 1: ...Installation and Maintenance Manual IAQ Series FADB 04007 6 A FADB 05011 6 A FADB 06015 6 A 6720220345 Revised 07 12 Fresh Air Damper System ...

Page 2: ...le of Contents Product Information 3 Features 3 Specifications 3 Application 3 Installation Considerations 4 Installation 5 Wiring 5 Controlling the Outside Air Damper 6 Homeowner Considerations 6 Contact your local Bosch Dealer or Installing Contractor for product support 7 Product Limited Warranty 8 ...

Page 3: ...nd routing of the air duct Figure 1 shows in general how to proDuCT InformATIon The Bosch fresh outside air damper system allows fresh air to be introduced into the home for natural healthy ventilation As the building codes of residences are getting more restrictive on air leakage for energy efficiency improvements fresh air can only enter the house as doors and windows are opened This typically l...

Page 4: ... and Bosch recommends that a qualified HVAC contractor or a professional engineer size the duct and verify that the additional pressure drop will not adversely affect the air flow delivered by the HVAC fan motor 3 The routing of the spiral duct must be considered Length of duct as well as any fittings will provide excess pressure drop to the HVAC duct system this may adversely affect the fan motor o...

Page 5: ... hole through the exterior wall for the intake hood and duct 4 Securely fasten the hooded louver intake to the exterior wall Installation IAQ Series 5 5 Route the required sized duct as determined by the HVAC contractor or professional engineer from the louver intake duct connection to the damper 6 Route the required sized duct as determined by the HVAC contractor or professional engineer from the...

Page 6: ...Simply turn the knob to the appropriate amount of outside air If the percentage of air is adjusted for a short time duration due to activities or possibly by smoke being created by burning food ensure that the controller is returned to the initial setting once the situation is back to normal Leaving the damper wide open when it is not needed can lead to IAQ issues by introducing humid air or dry a...

Page 7: ...ocation 3 Routinely check the bird screen underneath the hooded louver intake to ensure that there is not debris blocking the air flow Contact your local Bosch Dealer or Installing Contractor for product support Field Technical Support 954 776 5471 Monday Friday 8 am 5 pm EST Bosch 601 N W 65th Ct Ft Lauderdale FL 33309 www bosch climate us Contact your Local Bosch Dealer IAQ Series 7 Table 1 Repl...

Page 8: ...sts for removal reinstallation repair and replacement of the defective component or part 7 Electricity or fuel costs or any increases or unrealized savings in same for any reason whatsoever 8 Damage caused by excessive temperatures or pressures fuel or gas explosion electrochemical reaction water and air impurities electrical failures use during construction flooding or acts of God 9 Any damage or...

Page 9: ...PERSONS OR PROPERTY OR DAMAGES FOR LOSS OF USE LOST PROFITS INCONVENIENCE OR LOSS OF TIME Caution Note that any repaired or replaced product will be warranted for only the unexpired tem of the original warranty Caution Some states do not allow the exclusion of limitation of damages or limitations on how long an implied warranty lasts so the above limitations and exclusions may not apply to you WAr...

Page 10: ...Subject to change without prior notice Revised 07 12 6 720 220 345 10 IAQ Series Notes ...

Page 11: ...6 720 220 345 Revised 07 12 Subject to change without prior notice Notes IAQ Series 11 ...

Page 12: ...601 N W 65th Court Ft Lauderdale FL 33309 Phone 954 776 5471 Fax 954 776 5529 www bosch climate us ...

Reviews: