34
| UK
Your energy.
Optimized.
User Menu
Layout of the user menu
The user menu provides access to 5 functions:
Menu Function
Range
1
Setting of the chimney fan output for stage 1 (LOW)
35-100%
2
Setting of the chimney fan output for stage 2 (HIGH)
35-100%
3
Setting the pre-purge period for the chimney fan
0-999 s
4
Setting the post-purge period for the chimney fan
0-60 min
5
Displaying current alarm (see alarm overview page 42)
-
When the instructions refer to the menu numbers 1, 2, 3, 4 and 5 it is understood that these numbers refer to the user menus.
Operating the user menu
Setting up the operating function
Before you can use the EBC22 as a 2-stage speed regulator for Exodraft chimney fans, you must change
the operating function.
The procedure for setting up the operating function is described on page 22
Step
Press...
To...
1
Activate the user menu
2
and
Go to the menu item you wish to edit
3
Edit the menu item selected
4
and
Adjust the required set point
5
Confirm the required set point
6
To save the required set point: Press
again within 5 seconds
7
Return to operation screen.
NB: If you do not press
the EBC22 will automatically return to the operation screen
after 30 seconds
You can always undo an action (that you have not confirmed by pressing
) and return to the operation screen by pressing
Adjust the set points for user menu items 1–4 as shown in the example on the following page.
Alarms
For alarm handling (menu 5), see page 41-42
ATTENTION! Remember to set up the operating
function of the EBC22 as described on page 22
ATTENTION! If you do not press any buttons for 30 seconds, the EBC22
will automatically switch back to the operation screen.