Impulse Tests
Copper Test
271
WB Impulse Noise Test
Setting Test Parameters
The
Test Parameters
page allows you to set either the
WB Count
or
WB Histogram
test parameters, depending which tab is open.
To set the parameter values:
1.
From either the
WB Count
or
WB Histogram
tab, click the
Edit
Parameters
button to open the
Test Parameters
page.
2.
Set the parameter values as required.
3.
Tap
Close
to confirm and exit the page.
The page allows you to set the following parameters:
Noise Filter
lists the filter currently enabled. Options are:
None
,
ISDN-E
,
HDSL-F
,
ADSL-G
,
ADSL
,
ADSL2+
,
VDSL
,
VDSL2-8
,
VDSL2-12
,
VDSL2-17
,
VDSL2-30
.
Termination Resistance
allows you to define the resistance of the
dummy load connected to the line.
Termination
is either
Terminated
, if the termination resistance is
internal to the unit, or
Bridging
if additional termination resistance is
used to
bridge
onto live circuits with minimal interruption.
Test Duration
allows you to set the length of time to run the test from a
selection of values.