TDR Test
Copper Test
195
Manual TDR
Note:
In order to configure
Trace 1
as
Differential
, at least two traces must be
enabled.
Note:
If
Trace 1
is configured as
Differential
and no trace is held or loaded, then
Trace 1
will display the normal TDR trace.
Differential Color
option opens a color panel which allows you to
differentiate between
Trace 2
,
Trace 3
and
Trace 1
. If
Type
is
Normal
for
Trace 1
, its color is black and the color option is
disabled.
Trace 2/3
: When enabled the following parameters can be set:
Type
allows you to configure each trace as the following:
Hold
- using this trace to display static snapshots of the live normal
TDR (regardless of whether
Trace 1
is configured as
Normal
or
Differential
) or
Load
- displaying traces loaded from a file.
Offset
: Each trace has a configurable offset, ranging from -1.00 to
1.00. The offset for
Trace 1 (Live)
is fixed at 0.00. If three traces are
enabled, all with
Offset
:
0.0
, then all three traces will overlap.
Trace Color
option opens a color panel which allows you to
differentiate between all 3 traces.
Prompt When Loading
allows you to change TDR parameters to that
of the loaded file, either a
Single Trace
or
Trace Group
(multiple
traces) when enabled.
Clear Held/Loaded Traces
button clears the parameters set for all