Signal Test
226
FTB-610
WB Attenuation Test
Setting Cable Parameters
The
Cable Selection
page allows you to set cable parameters for the
Attenuation
test.
To set the Cable Setup values:
1.
From the
Copper
main menu
Test Groups
, select
Signal
test
.
2.
From the
Tests
menu, select
WB Attenuation
test.
3.
Tap
Select Cable
button to open the
Cable Selection
page.
4.
Edit the
Cable Parameters
as required.
5.
Tap
Close
to confirm and exit the page.
The page allows you to set or view the following parameters:
Cable Type
allows you to select a cable entry (with its associated
parameters) from the current
Cable Book
, to use for testing. The
selection is not saved when leaving the test. The current Cable Book
entry is shown by default.
Cable Fill Material
read-only entry is the type of material the cable is
filled with:
Aircore
,
Jelly
,
Pulp
,
5 PR
, or
2 PR
. Setup in the
Cable Book
.
Capacitance T-R
specifies a value for the capacitance per length
constant.