The RFL measurement used by the CableSHARK is referred to as a “separate good pair” test. This means
the user must have a good pair to compare against.
12.1.1 Setting up for a RFL Test
12.1.1.1 Disconnecting the Station Battery and the Customer
Before an RFL test can take place, the circuit that is to be tested must be disconnected from the CO station
battery and from the customer. The RFL test is an end-to-end test meaning that the CableSHARK is placed
at one end of the circuit (typically on the CO side of the circuit) and a strap is placed on the customer side of
the circuit.
IMPORTANT: Attachment of the strap should not take place until the CableSHARK has indicated how
to hook up the strap.
12.1.1.2..Connecting the CableSHARK to a Suspect Faulty Pair
To perform a RFL test, the user must determine what is the faulty pair and whether there is a good pair in
the bundle to connect to. The CableSHARK has two sets of connections on the rear of the unit. The 2 Wire
Line TX/RX is used to connect to a suspect wire pair to determine if it is faulty, and if so, where is the fault.
TIP - BLACK
GND - GREEN
RING - RED
F
IGURE
12.1.1.2A
–
2
W
IRE
TX/RX
C
ABLE
The initial connection to the circuit should be as follows using the three telco clip cable above.
Summary of Contents for CableSHARK P3
Page 1: ......
Page 10: ...VF DSL Cable Qualifier viii...
Page 12: ...VF DSL Cable Qualifier x...
Page 26: ...VF DSL Cable Qualifier 14...
Page 36: ...VF DSL Cable Qualifier 24...
Page 64: ...VF DSL Cable Qualifier 52...
Page 80: ...VF DSL Cable Qualifier 68...
Page 184: ...VF DSL Cable Qualifier 172...
Page 192: ...VF DSL Cable Qualifier 180...
Page 224: ...VF DSL Cable Qualifier 212...
Page 228: ...VF DSL Cable Qualifier 216...
Page 262: ...VF DSL Cable Qualifier 250 CSA Loop 6 CSA Loop 7 CSA Loop 8 Extended CSA Loop 9...
Page 263: ...CableSHARK P3 User Guide 251 Extended CSA Loop 10 Mid CSA Loop 0 Mid CSA Loop 1 Mid CSA Loop 2...
Page 264: ...VF DSL Cable Qualifier 252 Mid CSA Loop 3 Mid CSA Loop 4 Mid CSA Loop 5 Mid CSA Loop 6...
Page 265: ...CableSHARK P3 User Guide 253 ANSI Loop 2 ANSI Loop 3 ANSI Loop 4 ANSI Loop 5...
Page 266: ...VF DSL Cable Qualifier 254 ANSI Loop 6 ANSI Loop 7 ANSI Loop 8 ANSI Loop 9...
Page 267: ...CableSHARK P3 User Guide 255 ANSI Loop 11 ANSI Loop 12 ANSI Loop 13 ANSI Loop 15...
Page 268: ...VF DSL Cable Qualifier 256...
Page 286: ...VF DSL Cable Qualifier 274...
Page 292: ...VF DSL Cable Qualifier 280...
Page 294: ...VF DSL Cable Qualifier 282...
Page 316: ...VF DSL Cable Qualifier 304...
Page 318: ...VF DSL Cable Qualifier 306...
Page 319: ...CableSHARK P3 User Guide 307 Notes...
Page 320: ...VF DSL Cable Qualifier 308...