Section 1  Chemical Identi

fi

 cation / Company / Undertaking

Name

:  EZ Open Reducer Powder Pillow For Total Iron Test

Product code

: 486601 used in kit 486651

Company Name

: Industrial Test Systems, Inc.

1875 Langston Street, Rock Hill, SC 29730 USA

Phone

: (800) 861-9712, (803) 329-9712, 

Fax

: (803) 329-9743

eMail

: [email protected]

Section 2  Composition / Information on Ingredients

Hazardous Ingredients

Sodium Hydrosul

fi

 te (CAS 7775-14-6) 

 

8-13%

Sodium Thiosulfate (CAS 10102-17-7 or 7772-98-7) 

16-22%

Sodium Metabisulfate (CAS 7681-57-4) 

 

13-21%

Sodium Chloride (CAS 7757-82-6)   

 

31-50%

Sodium Dihydrogen Citrate (CAS 18996-35-5)   

9-15%

Section 3  Hazards Identi

fi

 cation

Main Hazards

: Harmful if swallowed. Irritating to eyes, respiratory 

system and skin. Contact with acids liberates toxic gases. Harmful to 

aquatic organisms

Section 4  First Aid Measures (Symptoms)

Skin Contact

: There may be mild irritation at the site of contact. 

Eye Contact

: There may be irritation and redness.

Ingestion

: There may be soreness and redness of the mouth and throat. 

There may be dif

fi

 culty swallowing. Nausea and stomach pain may 

occur. There may be vomiting.

Inhalation

: Absorption through the lungs can occur causing symptoms 

similar to those of ingestion.

Section 4  First Aid Measures (Action)

Skin Contact

: Wash immediately with plenty of soap and water.

Eye Contact

: Flush eyes with running water for 15 minutes. Call 

physician.

Ingestion

: Wash out mouth with water. Do not induce vomiting. If 

conscious, drink 1-2 glasses of water immediately. Call physician 

immediately.

Inhalation

: Remove to fresh air, give arti

fi

 cial respiration if necessary. 

Call physician.

Section 5  Fire Fighting Measures

Extinguishing media

: Suitable extinguishing media for the surrounding 

fi

 re should be used.

Exposure hazards

: In combustion emits toxic fumes.

Protection of 

fi

 re-

fi

 ghters

: Wear self-contained breathing apparatus. 

Wear protective clothing to prevent contact with skin and eyes.

Section 6  Accidental Release Measures

Personal precautions

: Refer to section 8 of MSDS for personal 

protection details. Do not create dust. Mark the contaminated area with 

signs and prevent access to unauthorised personnel. If outside do not 

approach from downwind.

Environmental precautions

: Do not discharge into drains or rivers.

Environmental precautions

: Transfer to a closable, labeled salvage 

container for disposal by an appropriate method.

Summary of Contents for Well EZ

Page 1: ...ADVANCED PHOTOMETER SYSTEM Well DIGITAL ACCURACY FOR RELIABLE WATER CARE QUICK START GUIDE...

Page 2: ...T EZ PHOTOMETER Thank you for your Well eXact EZ purchase This guide will quickly walk you through the technical details of your new photometer After initial set up test procedures and tips you will b...

Page 3: ...sure not to over tighten SAMPLE CELL 4 ML Built in plastic 4mL cell for collecting your water sample LCD DISPLAY Displays results and test name LIGHT SOURCE Uses 525nm wavelength and 11mm path length...

Page 4: ...ith the water sample to be tested and FILL to the top to begin test 2 In bright light situations use cell cover for zeroing and reading TIP FILL DIP READ 3 SELECT TEST Press and re press the button un...

Page 5: ...sult is automatically stored in the PH1 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the e...

Page 6: ...econds Ignore result displayed Clean cell with Distilled Vinegar 5 or 0 1N HCl before filling the meter with the sample to be tested If running multiple tests in a row using the same water sample the...

Page 7: ...AD Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the t...

Page 8: ...the water sample to be tested and FILL to the top to begin test 2 3 SELECT TEST Press and re press the button until the display shows No3 ZERO METER Press and the LCD Display reads 0 00PPM indicating...

Page 9: ...ored in the No3 menu After testing is complete rinse the sample cell immediately and clean with brush 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXac...

Page 10: ...ve the most accurate result TIP FILL CELL Rinse the cell 3 times with the water sample to be tested and FILL to the top to begin test 2 ZERO METER Press and the LCD Display reads 0PPM indicating the m...

Page 11: ...sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back a...

Page 12: ...water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Well eXact EZ 3 SELECT TEST Press and re press the button until the display shows T...

Page 13: ...ys 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Total Hardness This result is automatically stored in the TH5 menu After testing is complete rinse the sample cell immediately...

Page 14: ...iceably smaller or larger in width than the normal strips in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tab...

Page 15: ...t in the Well eXact EZ we offer an industry leading 2 year warranty We built the Well eXact EZ to be easy accurate and environmentally friendly We have achieved this by utilizing our patented eXact St...

Page 16: ...faulty or otherwise defective contact ITS by phone 1 803 329 9712 Ext 0 or email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS D...

Page 17: ...pain may occur There may be vomiting Inhalation Absorption through the lungs can occur causing symptoms similar to those of ingestion Section 4 First Aid Measures Action Skin Contact Wash immediately...

Page 18: ...ns Conditions to avoid Heat Materials to avoid Oxidising agents and acids Haz decomp products In combustion emits toxic fumes Section 11 Toxicological Information Engineering Measures EZ Open Reducer...

Page 19: ...latory information given above only indicates the principal regulations specifically applicable to the product described in the material safety data sheet The user s attention is drawn to the possible...

Page 20: ...up to date product information SENSAFE ITSSENSAFE Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 1 800 861 9712 Inside the U S A 1 803 329 9712 Outside the U S A Fax 1 803 329 974...

Reviews: