FOR BEST ACCURACY

The Well eXact

®

 EZ photometer has a 5 minute auto-shutoff timer.

Each test menu can store 20 results. To retrieve the stored results, go to the 

desired test using the MENU key. When the desired test is displayed, press 

and hold down the MENU key. Continue holding down the MENU key to 

scroll the stored results for that test, starting with the most recent result. The 

meter will display, from memory, the last 20 readings in sequence beginning 

with -20, which is the latest result, followed by -19, which is the 2nd latest 

result, etc; and 

fi

 nally -01, which is the oldest result retained. Only the last 20 

readings are stored in each menu. This meter is able to store 100 results in 

memory (20 in each menu).
Before testing, rinse the meter sample cell with the sample water 3 times.
Always 

fi

 ll the cell to capacity (4mL); be careful not to splash liquid 

over the side.
Test immediately after 

fi

 lling the cell with the water sample. 

To obtain optimal accuracy when testing outdoors (sunlight), use the cell 

cover when zeroing and reading the sample.
Due to the strip slitting process, you may 

fi

 nd one or two strips that are 

noticeably smaller or larger in width than the normal strips in the bottle. These 

should be discarded. Using these strips may give unreliable results.
Meter is not compatible for use with powder pillows, tablets, or liquids from 

other manufacturers.
Dip strip for entire countdown.
Each eXact

®

 Strip Micro is valid for ONLY one test. Discard strip after use.

Dry the outside of the meter before storage.
Remove batteries before storing for prolonged periods.
Store the meter and test materials out of direct sunlight and away from 

chemical storage areas. 
Minimize exposure of meter and test reagents to heat above 90°F (32°C).
When installing batteries, verify the O-ring is still attached to the screw 

before tightening.
Cleaning the cell with water and brush after each test is recommended for 

best accuracy and prior to storage of unit.

TECHNICAL SUPPORT

Please visit 

sensafe.com/photometers/well-exact-ez/

for the latest technical information and how-to-videos. 

For additional technical support, call (803) 329-9712.

Industrial Test Systems, Inc.

1875 Langston Street, Rock Hill, SC 29730
800-861-9712 or 803-329-9712  
[email protected] | sensafe.com

ITS Europe, Ltd.

The UK Centre for Homeland Security
Building 7, Chilmark, Salisbury, 
Wiltshire SP3 5DU UK  +44 1722 717911  
[email protected] | itseurope.co.uk

   

  C

EL

EB

RAT

ING EXCELLE

NC

E   

years

28

1989

2017

Manufacturing quality products since 1989

Summary of Contents for Well EZ

Page 1: ...ADVANCED PHOTOMETER SYSTEM Well DIGITAL ACCURACY FOR RELIABLE WATER CARE QUICK START GUIDE...

Page 2: ...T EZ PHOTOMETER Thank you for your Well eXact EZ purchase This guide will quickly walk you through the technical details of your new photometer After initial set up test procedures and tips you will b...

Page 3: ...sure not to over tighten SAMPLE CELL 4 ML Built in plastic 4mL cell for collecting your water sample LCD DISPLAY Displays results and test name LIGHT SOURCE Uses 525nm wavelength and 11mm path length...

Page 4: ...ith the water sample to be tested and FILL to the top to begin test 2 In bright light situations use cell cover for zeroing and reading TIP FILL DIP READ 3 SELECT TEST Press and re press the button un...

Page 5: ...sult is automatically stored in the PH1 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the e...

Page 6: ...econds Ignore result displayed Clean cell with Distilled Vinegar 5 or 0 1N HCl before filling the meter with the sample to be tested If running multiple tests in a row using the same water sample the...

Page 7: ...AD Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the t...

Page 8: ...the water sample to be tested and FILL to the top to begin test 2 3 SELECT TEST Press and re press the button until the display shows No3 ZERO METER Press and the LCD Display reads 0 00PPM indicating...

Page 9: ...ored in the No3 menu After testing is complete rinse the sample cell immediately and clean with brush 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXac...

Page 10: ...ve the most accurate result TIP FILL CELL Rinse the cell 3 times with the water sample to be tested and FILL to the top to begin test 2 ZERO METER Press and the LCD Display reads 0PPM indicating the m...

Page 11: ...sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back a...

Page 12: ...water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Well eXact EZ 3 SELECT TEST Press and re press the button until the display shows T...

Page 13: ...ys 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Total Hardness This result is automatically stored in the TH5 menu After testing is complete rinse the sample cell immediately...

Page 14: ...iceably smaller or larger in width than the normal strips in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tab...

Page 15: ...t in the Well eXact EZ we offer an industry leading 2 year warranty We built the Well eXact EZ to be easy accurate and environmentally friendly We have achieved this by utilizing our patented eXact St...

Page 16: ...faulty or otherwise defective contact ITS by phone 1 803 329 9712 Ext 0 or email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS D...

Page 17: ...pain may occur There may be vomiting Inhalation Absorption through the lungs can occur causing symptoms similar to those of ingestion Section 4 First Aid Measures Action Skin Contact Wash immediately...

Page 18: ...ns Conditions to avoid Heat Materials to avoid Oxidising agents and acids Haz decomp products In combustion emits toxic fumes Section 11 Toxicological Information Engineering Measures EZ Open Reducer...

Page 19: ...latory information given above only indicates the principal regulations specifically applicable to the product described in the material safety data sheet The user s attention is drawn to the possible...

Page 20: ...up to date product information SENSAFE ITSSENSAFE Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 1 800 861 9712 Inside the U S A 1 803 329 9712 Outside the U S A Fax 1 803 329 974...

Reviews: