background image

16

©

2017, Industrial Test Systems, Inc. Printed in USA

BUILT IN SAMPLE CELL

The built-in sample cell is made of transparent plastic; 

the sturdy cell design will last for over 20,000 readings. 

Our studies have shown that scratches on the cell will not 

compromise the accuracy of your results because of the 

cell’s 

fi

 xed position.

WARRANTY (2 YEARS)

Registration of your eXact

®

 photometer must be received within 30 days from 

date of purchase to activate the warranty. Registration is available over the 
phone (+1-803-329-9712 Ext. 0) or online at 

sensafe.com/micro/warranty/

 

(Personal data is kept con

fi

 dential). The eXact

®

 photometer is warranted to 

be free from defects in materials and workmanship for a period of two (2) 
years from the date of purchase by the customer. ITS will repair or replace, 
at its discretion, product which is deemed to be faulty due to manufacturing 
defect. Warranty does not cover product damage caused by abuse (such as 
crushing a tablet in the cell), battery corrosion damage, or improper use. If 
the meter is faulty or otherwise defective contact ITS by phone (+1-803-329-
9712 Ext. 0) or email ([email protected]) to describe the problem and obtain 
a return authorization form before returning the photometer to ITS. Damage 
caused by improper packing of the photometer for return shipment to ITS 
will not be covered by the warranty. Customer is responsible for shipping 
charges to ITS. ITS pays postage when photometer is returned to customer. A 
maximum processing fee of $75 will be charged for repair or replacement of 
non-registered photometers and damages not covered by this warranty. The 
repair or replacement of the photometer will not extend or renew the period of 
guarantee. This warranty does not affect your statutory rights. The warranty is 
not transferable.

ITEM

INCLUDES

PART NO.

Standard 

Carrying case

Blue carrying case with foam inserts 
(holds up to 7 bottles)

486111

XL 

Carrying case

Black carrying case with foam inserts
(holds up to 14 bottles)

486001

Made of sturdy material lined with 

foam, the carrying case offers storage 

for a Well eXact

®

 EZ photometer and 

eXact

®

 Micro reagents.

CARRYING CASE FOR WELL EXACT

®

 EZ

Store all your necessary reagents together with your 

Well eXact

®

 EZ in our convenient carrying case!

TIP

 

ABOUT

Summary of Contents for Well EZ

Page 1: ...ADVANCED PHOTOMETER SYSTEM Well DIGITAL ACCURACY FOR RELIABLE WATER CARE QUICK START GUIDE...

Page 2: ...T EZ PHOTOMETER Thank you for your Well eXact EZ purchase This guide will quickly walk you through the technical details of your new photometer After initial set up test procedures and tips you will b...

Page 3: ...sure not to over tighten SAMPLE CELL 4 ML Built in plastic 4mL cell for collecting your water sample LCD DISPLAY Displays results and test name LIGHT SOURCE Uses 525nm wavelength and 11mm path length...

Page 4: ...ith the water sample to be tested and FILL to the top to begin test 2 In bright light situations use cell cover for zeroing and reading TIP FILL DIP READ 3 SELECT TEST Press and re press the button un...

Page 5: ...sult is automatically stored in the PH1 menu After testing is complete rinse the sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the e...

Page 6: ...econds Ignore result displayed Clean cell with Distilled Vinegar 5 or 0 1N HCl before filling the meter with the sample to be tested If running multiple tests in a row using the same water sample the...

Page 7: ...AD Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back and forth motion 2 strokes per second until the t...

Page 8: ...the water sample to be tested and FILL to the top to begin test 2 3 SELECT TEST Press and re press the button until the display shows No3 ZERO METER Press and the LCD Display reads 0 00PPM indicating...

Page 9: ...ored in the No3 menu After testing is complete rinse the sample cell immediately and clean with brush 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXac...

Page 10: ...ve the most accurate result TIP FILL CELL Rinse the cell 3 times with the water sample to be tested and FILL to the top to begin test 2 ZERO METER Press and the LCD Display reads 0PPM indicating the m...

Page 11: ...sample cell immediately 7 DIP STRIP AND PRESS READ Press to initiate a 20 second countdown and simultaneously DIP the eXact Strip by submerging all pads in the sample then use a gentle constant back a...

Page 12: ...water sample to be tested and FILL to the top to begin test 2 1 POWER ON PHOTOMETER Press the button to power on the Well eXact EZ 3 SELECT TEST Press and re press the button until the display shows T...

Page 13: ...ys 1 Remove and discard the strip 6 READ RESULTS READ result displayed as Total Hardness This result is automatically stored in the TH5 menu After testing is complete rinse the sample cell immediately...

Page 14: ...iceably smaller or larger in width than the normal strips in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tab...

Page 15: ...t in the Well eXact EZ we offer an industry leading 2 year warranty We built the Well eXact EZ to be easy accurate and environmentally friendly We have achieved this by utilizing our patented eXact St...

Page 16: ...faulty or otherwise defective contact ITS by phone 1 803 329 9712 Ext 0 or email its sensafe com to describe the problem and obtain a return authorization form before returning the photometer to ITS D...

Page 17: ...pain may occur There may be vomiting Inhalation Absorption through the lungs can occur causing symptoms similar to those of ingestion Section 4 First Aid Measures Action Skin Contact Wash immediately...

Page 18: ...ns Conditions to avoid Heat Materials to avoid Oxidising agents and acids Haz decomp products In combustion emits toxic fumes Section 11 Toxicological Information Engineering Measures EZ Open Reducer...

Page 19: ...latory information given above only indicates the principal regulations specifically applicable to the product described in the material safety data sheet The user s attention is drawn to the possible...

Page 20: ...up to date product information SENSAFE ITSSENSAFE Industrial Test Systems Inc 1875 Langston Street Rock Hill SC 29730 1 800 861 9712 Inside the U S A 1 803 329 9712 Outside the U S A Fax 1 803 329 974...

Reviews: