ES2030 SV
Display and modification of the basic settings
24
15. Definition of output functions
The controller is not equipped with the necessary additional relay for output
functions as standard. The controller can be expanded with this relay by fitting the
IF expansion card (connector: OUT1 and connector OUT2).
The outputs may be used for one of the following functions :
Each function can only be used once.
NOTE: Program steps 15-20 can only be selected if the IF expansion card has
been installed in the controller.
Output relay 1
Place the cursor under the required output function.
AP
= additional program
RG
= regeneration
FP
= flow pulse
WA
= warning
PU
= flushing
NOTE: The functions ‘flow pulse’ and ‘flushing’ can only be selected if the system
Is fitted with a water meter.
NOTE: This step will not be selected if the relay is programmed for valve function
in step 2.1
Output relay 2
Place the cursor under the required output function.
NOTE: The functions ‘flow pulse’ and ‘flushing’ can only be selected if the system
Is fitted with a water meter.
NOTE: This step will not be selected if the relay is programmed for valve function
in step 2.1
Outputs active
You can determine whether the output relays are to be energized or de-energized
when the function is active.
“ - “ = Function active when relay energized
“ | “ = Function active when relay de-energized
Step no.: 15.1
AP RG FP WA PU
Step no.: 15.3
OU1 - OU2 -
Step no.: 15.2
AP RG FP WA PU
9.3 / 10.4
IF2030
card
Y
N
21.1
AP RG
PU
15.1
FP WA
AP RG
PU
15.2
FP WA
16.1-20.1
Output1 Output2
- | - |
15.3