Functional characteristics
TIG Synergic operating principle
Item No.: 099-000155-EWM01
27
5.2.4
Select welding current
The user has two options for setting the required welding current:
• Using the sheet metal thickness
• Directly as welding current
NOTE
The welding current is displayed in the left-hand display. The “Material thickness”
parameter can be selected in the right-hand display.
Control element Action
Result
Display (right)
VOLT
JOB
PROG
X x
Press button until signal light
Material Thickness comes on.
Material thickness in
mm is displayed.
Set welding current or sheet metal thickness. Welding current and
sheet metal thickness
are displayed
5.2.5
Welding data display
The following welding parameters can be displayed before (nominal values), during (actual values) or
after welding (hold values):
“Left-hand display”
Parameter Before
welding
(nominal values)
During welding
(actual values)
After welding
(hold values)
Welding current
z
z
z
Parameter times
z
- -
Parameter currents
z
- -
“Right-hand display”
Material thickness
z
z
z
Welding voltage
z
z
z
JOB number
z
- -
Program number
z
- -
When the settings are changed (e.g. welding current) after welding when the hold values are displayed,
the display will be switched to the relevant nominal values.
If the “Program number” signal light is on in addition to the “Material thickness” signal light, the user is in
program mode (programs 1-15, see chap. “Welding programs”).
If the “JOB number” signal light is on in addition to the “Material thickness” light, the user is in a JOB in
the free memory (JOBs 128 to 256, see chapter “Creating a new JOB in the free memory”).