7.4.5 Triac monitoring
Description
Each zone has its own triac monitoring (triac = electronic power switch
which directly controls the heating circuits), in order to be able to detect a
possible control interruption of a zone, e.g. nozzle heating.
A defective triac is detected if a current flows without controlling the out-
puts.
If a current flows, this zone is switched off and an error message
is
displayed.
7.5
Special functions
7.5.1 BOOST
Description
By executing the boost function, the temperature in selected zones is
raised by a fixed value - the boost offset (parameter
) - for a certain
time (parameter
).
The control is carried out via the "Boost button".
Parameter
Zone parameter
Settings
Boost-Offset
0…50K,
Default value=0K
Boost-Duration
0…900s,
Default value=60s
pro CONTROL BASIC Manual
page 33
7.5.2 STANDBY
Description
The use of the standby function is recommended in order to protect the
tools and the raw material they contain as well as to reduce energy costs
during downtimes. The standby temperature can be set according to the
materials used.
It is controlled via the "Standby button". The standby function always
applies to all zones.
Parameter
Zone parameter
Settings
Standby
temperature
0…300°C
Default value=20°C
7.5.3 Default parameter
Description
System parameter
With this parameter a reset of all settings to the factory setting can be
initiated.
1 = Load default parameters
Parameter
System parameter
Settings
Default parameter
0, 1
Default value: 0