pro CONTROL BASIC Manual
page 20
5.7
Boost
Step
Operation
Description
1.
Select the zone(s) as described in 5.1
2.
Pressing the Boost button increases the setpoint value for
the selected zones by the value stored in the zone param-
eters.
The duration of the boost process is stored in parameters.
If necessary, the standby mode is ended by the boost.
The setpoint display SET flashes alternating with the dis-
play
„
bSt
“.
5.8
Standby
Step
Operation
Description
1.
Pressing the standby button lowers the setpoint to the
value stored in zone parameters.
Confirming again deactivates the standby mode.
The standby mode terminates the boosting if necessary.
The standby mode can also be activated via the digital 24V
control input.
The setpoint display SET flashes alternating with the dis-
play
„
Stb
“.
pro CONTROL BASIC Manual
page 21
6 Warning and error messages
The pro CONTROL BASIC controllers provide information about the current status via status
and 7-segment display. Warnings and alarms are shown as abbreviations in the 7-segment
display. In addition, the LED band indicates the controller status in green, yellow and red. In
the standard state, the LED band lights up green. An existing warning is displayed in yellow.
Warning messages alert the plant operator to possible problems. However, production
operation is continued. A suddenly occurring alarm is displayed in red. If it occurs, the plant
operator must intervene. For critical alarms, an error acknowledgement or a device restart
may be necessary. The following subchapters contain a detailed list of all warnings and
alarms.
6.1
Warnings
Warnings are shown in yellow
by the status display (LED stripe).
7 segm.
display
•
Description / Causes
Notification
contact
Positive temperature deviation
•
The actual value of the sensor is above the tol-
erance band set as zone parameter
.
Warning is
displayed
-
Tolerance band (zone parameter
)
too small,
if oscillation occurs due to the process.
Negative temperature deviation
•
The actual value of the sensor is below the toler-
ance band set as zone parameter
.
Warning is
displayed
-
Controller is in the heat-up phase
-
Tolerance band (zone parameter
)
too small
-
Heat output may not be sufficient
-
Heating could be defective
-
Sensor not in contact with this zone
Broken sensor
•
No connection to the sensor.
Warning is not
displayed
-
No sensor connected
-
Sensor cables / connecting cable defective
-
Sensor plug connections defective
Zone operates with the average output level in
manual mode
21
pro CONTROL BASIC hot runner controllers – Operating manual