![EWIKON pro CONTROL basic Operating Manual Download Page 17](http://html1.mh-extra.com/html/ewikon/pro-control-basic/pro-control-basic_operating-manual_2448023017.webp)
pro CONTROL BASIC Manual
page 16
5.3
Setpoints
Step
Operation
Description
1.
Select the zone(s) as described in 5.1
2.
Use the buttons to set the setpoint to the desired value.
The display flashes, indicating that the value has not yet
been accepted.
3.
Confirm the entry
The display stops flashing
4.
Press the Home button to return to the overall display of all
zones.
pro CONTROL BASIC Manual
page 17
5.4
Output rate
Step
Operation
Description
1.
Select the zone(s) as described in 5.1
2.
Selection of the operating mode.
Operate until manual mode
is displayed.
3.
Confirm selection
4.
Switching the zone display to
Current (I) and output rate (Y)
5.
Use the buttons to set the output level to the desired value.
The display flashes, indicating that the value has not yet
been accepted.
6.
Confirm the entry.
The display stops flashing.
7.
Press the Home button to return to the overall display of all
zones.
5.5
Controller outputs
Step
Operation
Description
1.
Activating / deactivating the controller outputs either
switches on all heating zones in control mode and manual
operation or switches off all zones.
17
pro CONTROL BASIC hot runner controllers – Operating manual