4.2
Operating and display elements
The operation as well as all display elements of the hot runner controllers is carried out via
the soft keys on the front of the housing. The following illustration shows the front view of a 6-
zone controller, from which all operating and display elements are shown.
Figure 3
–
Operating and display elements
pro CONTROL BASIC Manual
page 11
4.2.1 Display elements
4.2.1.1 Status display
The status of the controller is indicated by a LED strip in the front. In control mode, this indi-
cator lights up green. In case of a warning or alarm, the display changes to yellow or red
(traffic light status).
Green signals all is well. The controller operates in
normal mode.
Yellow indicates warning messages that indicate a
deviation from the normal state.
Red indicates alarms. Depending on the fault, outputs
of corresponding zones are also deactivated.
4.2.1.2 Zone display
Each heating zone has two 7-segment displays and four LEDs for status indication. The 7-
segment displays show either the setpoint and actual value or the heating current and de-
gree of operation. In addition, the four LEDs can also be used to display the states shown
below.
Figure 4
–
Zone display
10
pro CONTROL BASIC hot runner controllers – Operating manual