7.1.2 Fahrenheit display
Description
This parameter indicates the temperature unit in which the controller is
displayed and operated. During operation, the setting can also be read
off via LED indicators on the display.
•
0:
°C
•
1:
°F
Parameter
System parameter
Settings
Fahrenheit-display
0 / 1, Default value = 0
→
°C
7.1.3 Thermocouple type
Description
The
parameter specifies the type of thermocouples used for the en-
tire controller.
Parameter
System parameter
Settings
Thermocouple type
0:
Fe/CuNi Typ J
1:
Ni/CrNi Typ K with tempera-
ture range max. 800°C
Default value = 0
pro CONTROL BASIC Manual
page 27
7.2
Control behaviour
7.2.1 Control parameters P I D
Description
The automatic determination of the control parameters P I D is called
classification. It is performed automatically after the controller outputs are
switched on and overwrites all previous settings of the control parame-
ters.
PID-Parameter
When classifying the zones, the controller sends a defined heating im-
pulse to each zone in order to automatically determine the heating
behaviour of e.g. the nozzle or manifold. The controller determines the
suitable control parameters for P, I and D and stores them in the parame-
ters
,
and
.
The process can be recognized by the flashing green LED band and can
take up to 60s for large, sluggish objects. The determined classification
can be viewed for each zone under Parameter
.
Activate and deactivate classification
To obtain special settings of the P, I and D parameters in any case, the
classification per zone can be switched off with the parameter
= "0".
Parameter
Zone parameters
Settings
P-Band
0…100%
Tn Reset time
0…999s
Tv Derivative time
0…999s
Activate classification
OFF = 0
ON = 1
Default value = 1
Classification of the zone
Read only
7.2.2 Output level
Description
The parameter specifies the output level for manual operation. If the con-
troller is already in manual mode, the setting of
can also be made as
described in section 5.4.
Parameter
Zone parameters
Settings
Output level
0…100%
Default value: 0%
7.2.3 Maximal output level
Description
This parameter limits the maximum output power of the heaters via the
output level.
Parameter
Zone parameter
Settings
Maximal output level
0…100%
Default value: 100%
26
pro CONTROL BASIC hot runner controllers – Operating manual