17
4.0 Structure a n d fun ctio n
4.6 Operating elements
The Ewellix operating devices are available as accessories
for telescopic pillars CPMA and CPMB. The desk switch is
designed to be fixed on a table, and the foot switch is de-
signed to be placed on the floor or fixed on a flat surface
close to the floor. The hand switch is shaped, so that unin-
tentional pushing is avoided. If you have any queries, please
consult the corresponding chapter on accessories.
4.7 Options
Options can be recognized from the type designation on the
product label.
Voltage
There are two voltage options for this telescopic pillar: 100-
240 V AC and 24 V DC. The telescopic pillar CPMA and
CPMB is always equipped with a mains cable through.
IMPORTANT: The mains supply must be connected from
only one side at a time.
Load
The telescopic pillars CPMA and CPMB in voltage 100–240
V AC are designed for 1 000 N or 2 000 N. The telescopic
pillars CPMA and CPMB in voltage 24 V DC are designed for
2 000 N.
Tube set
The tube set is defined as a two-section tube set.
Stroke length
The available stroke length for CPMA and CPMB 100–240 V
AC is from 230 mm up to 400 mm in 10 mm steps. The avail-
able stroke length for CPMA and CPMB 24 V DC is from 200
mm up to 400 mm in 10 mm steps.
Motor orientation
The motor of telescopic pillars CPMA and CPMB can be
placed in either the inner or outer tube.
Operating device orientation
The operating device socket is normally placed on the side
of the motor. With the option operating device socket at
both sides, one socket for operating device will be placed
on the outer tube and the other on the inner tube base plate.
This allows connection for using operating devices simulta-
neously at the bottom and the top.
LAN cable through
The optional LAN cable through is only available for CPMA.
On each base plate is mounted a female RJ45 socket. The
combination of optional LAN cable through with option op-
erating device on both sides is not possible.
4.8 Accessories
Mains cable straight
2,5 m mains cables for 100-240 V AC with plugs for specific
countries can be supplied as accessories. The mains cable
is intended to be used in the base plate to facilitate the con-
nection to the terminal mains feed through.
Detachable mains cord straight
Detachable mains cord with plug for specific countries and
IEC-60320 C13 plug can be supplied as accessories. It is in-
tended to be used together with the socket box inlet.
Desk switch with LED cable 0,5 m or 1,0 m
The desk switch is defined as an operating element to be
connected on telescopic pillars CPMA and CPMB and
mounted below the tabletop.
Hand switch with LED cable coiled 1,3 m
The telescopic pillars CPMA and CPMB can be controlled
with a hand switch.
Foot switch without LED cable coiled 1,3 m
The telescopic pillars CPMA and CPMB can be controlled
with a foot switch.
Mounting plate
The purpose of the mounting plates is to ensure that the fas-
tened application is seated fully and solidly. The mounting
plate will be fixed to the top or bottom base plate of the tele-
scopic pillar with four fastening screws M6.
Socket box inlet: IEC, RJ45 LAN, RJ45
operating device
The socket box inlet facilitates connection for detachable
mains cord with plug IEC-60320 C13 on one side, RJ45 LAN
and RJ45 connection for operating device on the other side.
A metal plate is integrated and placed between the base
plate and the application, fastened with four M6 screws.