23
6.0 In s ta llation an d fir st o p eration
1. Connect the corresponding operating device to the tele-
scopic pillars CPMA and CPMB on the terminal for the
operating device (d6). Place the operating device cable
in the LAN cable and operating device cable channel
(d5). If LAN cable through is selected on the CPMA, then
place the LAN cable, with short bending protection on
the plug, in the LAN socket (d7).
Base plate view telescopic pillars CPMA and
CPMB
Telescopic pillars
CPMA and CPMB
for 100-240 V AC
d1. Terminal for mains cable neutral, N for 100-240 V AC
d2. Terminal for mains cable earth, PE for 100-240 V AC
d3. Terminal for mains cable phase, L for 100-240 V AC
d4. Mains cable channel
d5. LAN cable and operating device cable channel
d6. Terminal for operating device and terminal for operating
device through on the opposite side of the motor
mounted base plate (only if corresponding option se-
lected)
d7. Terminal for LAN through (only if corresponding option
selected of telescopic pillar CPMA )
d8. Terminal for mains cable, – for 24 V DC
d9. Terminal for mains cable earth, PE for 24 V DC
d10. Terminal for mains cable, + for 24 V DC
2. Connect the mains cable to the mains terminals.
For telescopic pillars CPMA and CPMB 100-240 V AC:
First, connect mains cable PE with PE terminal, then
connect mains cable N with N terminal and finally, con-
nect mains cable L with terminal L.
For telescopic pillars CPMA and CPMB 24 V DC:
First connect mains cable PE with PE terminal, then con-
nect mains cable – with – terminal and finally, connect
Telescopic pillars CPMA
and CPMB
for 24 V DC
d1
d8
d2
d9
d3
d4
d5
d7
d6
d10
mains cable + with te.
Place the mains cable in the mains cable channel (d4) for
strain relief. Choose the cable channel to the left or right
side of the base plate according to the application.
Fit a cable tie in order to secure the wires. The cable tie
should be secured as close to the terminal as possible.
WARNING
Electric shock hazard
Ensure that cables cannot get pinched or damaged. Check that
the mains voltage corresponds to the nominal value on the product
label. Ensure that the strain relief clamp and cabling are placed
correctly.
You can find the nominal values in the appendix
(⮑ Equipment and operating data, page 34).
IMPORTANT: The mains supply must only be provided from
one side. The mains cable wires must be stripped from the
insulation for a length of 5–10 mm to ensure a reliable con-
nection, and the PE connection wire needs to be 10 mm
longer than the others. When using your own mains cable,
comply with cable specification of maximum 2,5 m length,
outside diameter 8,2 mm +/–0,5 mm with stranded wire
cross section at least 3×1 mm
2
.
Insert conductor
Push