30
CPMA a n d CPMB
8.2.2 Inspections and readings
• To be performed only by professional electricians.
• To be conducted according to the applicable standards
and regulations.
• To be fully documented.
Complete the following entries in the service log:
• Name of the executing body (company, department)
• Names of the staff on duty
• Identification of the device/system (type, serial number, in-
ventory number) and the respective accessories
• Completed inspections and readings
• Scope and results of the inspections
• Measuring method, measuring device, measuring results
for readings
• Overall assessment / verification of all functions compared
to specifications
• Date and signature of the assessor; personal coding is
a viable alternative for IT applications.
IMPORTANT: Damage can be caused by incorrect cleaning
• Do not use aggressive cleaning agents. Water used for
cleaning, including chemical additives, must be pH-neu-
tral.
• The telescopic pillar must not come in contact with any liq-
uids during retraction or extension.
• Only use the auxiliary materials listed by the manufacturer.
• No steam jets or pressure washers to be used for cleaning.
• Use of other cleaning agents or devices only with the man-
ufacturer’s approval.
8.3 Measures following
maintenance
Upon completion of the maintenance work, the following
steps should be performed prior to restarting the device.
1. Check all previously loosened screw connections for a
tight fit.
2. Ensure that all used tools, materials and other equipment
have been removed from the work area.
3. Clean work area and remove potential spills such as liq-
uids, processing materials or similar substances.
4. Ensure that all the system’s safety measures are working
satisfactorily.
5. Check all functions against the product specifications.
6. Document the inspections in the service log.