8
CA S M -1 0 0
NOTE
The technical data (dimensions, weight, output, connection
values, etc.) can be found in the drawings and data sheets at the
end of this manual (⮑ 11 Appendix, page 27).
3.1 Operating conditions
Environment
Information
Value
Unit
Temperature range
–40 to +50 °C
Relative atmospheric humidity,
maximum (no build up of condensation)
95
%
WARNING
The surface temperature of the actuator should not exceed 60°C.
Exceeding this temperature will decrease the life rating of the
actuator as described in the performance diagram.
WARNING
The actuator is not intended to be applied with side loads. Side
loads must be avoided by proper guiding and mounting. If side
loads occur, this might result in decreased lifetime or structural
damage of the actuator.
3.0 Technical data
3.2 Product labels
3.2.1 Linear unit label
1
4
3
2
The product label provides the following information:
1. Type designation
Line 1: Linear unit
Line 2: Gearbox
Line 3: Motor kit
2. Serial number
3. Manufacturing date (month/year)
4. QR-code (with type designation)
3.2.2 Gearbox label
CAM- GS-CBA
0133301
i=3.892
BA123456
1714-00
23.04.2019
1
4
3
6
7
2
5
The gearbox product label can always be found on the prod-
uct, also if the gearbox was ordered separately. The product
label provides the following information:
1. Type designation
2. Article number
3. Ratio
4. Serial number
5. Internal use code
6. Manufacturing date
7. Bar code