3704-IG-001 Installation and User Manual
Page 4
Specifications
Product Code
Product Code
3704-A00XX
Electrical
*
Voltage
Current (Rated)
Current (Simulated Level 1)
208-240 VAC
30A
7A@208-240 VAC (On Command)
Connections
Line 1 and 2, Ground
Required Service (Breaker Panel)**
2-pole 40A breaker Non GFCI on a dedicated circuit/20A Switchable by Dip
Settings
Stand By Power (Per EVSE)
Max Rated Power
Less than 10W typical (without communication/Payment Module/Gateway
operating)
7.2kW
Safety Features
Over Current Disconnect
32A
Surge Protection
6KV @ 3000A
Ground Fault
Internal 20 mA CCID with auto re-closure (three attempts)
Compliance
Safety
IEC/UL/CSA C22.2 61010-1, UL2594, UL2231-1, UL2231-2, NEC Article 625, SAE J1772
EMC
FCC Part 15 Class A, Canadian ICES-003
Communications
ZigBee
FCC ID: MCQ-PS2CTH, IC: 1846A-PS2CTH
Environmental
Operating Temperature
-22° to 122° F (-30° C to 50° C) ambient
Operating Humidity
Up to 95% non-condensing
NEMA Rating
NEMA 3R
General
Dimensions
37 in (h) x 10.5 in (w) x 10.5 in (d) (Excluding Pole)
Weight
Mounting
32 lbs. (Excluding Pole)
Wall, Surface-mounted Pole
*
Observe all required Lockout/Tagout procedures while making any electrical connections or servicing the unit.
**
Dual pole-mounted chargers requires two breakers.