25
© by NECTA VENDING SOLUTIONS SpA
0303 204-00
Fig. 27
1
Transformer primary winding protection fuse
2
Transformer secondary winding protection fuse
3
Line fuse
4
Line fuse
5
RS232 serial port
6
Illuminated main switch
Fig. 28
1
Anti-intrusion grille
2
Dispensing compartment
Fig. 29
1
Evaporator
2
Fan
3
Condenser
4
Dispensing compartment
POWER SUPPLY UNIT
The fuses and the switch at the front of the power supply
unit have the functions indicated below.
When replacing any fuses the power supply cable
must be disconnected from the mains.
To access the inside of the power supply unit, remove the
product dispensing compartment proceeding as described
in the chapter “Access to the cooling unit”.
ACCESS TO THE COOLING UNIT
At least every six months it is necessary to clean the
ventilation grilles of the cooling system using a vacuum
cleaner or compressed air.
If for any reason the cooling unit need to be accessed from
the machine, do as follows:
- remove the last tray;
- remove the anti-theft grille;
- undo the fastening screws from the product dispensing
compartment and remove it;
- for re-assembly, proceed in the opposite way.
Summary of Contents for Snakky SL
Page 2: ......
Page 54: ...Sx36901...
Page 55: ...Snakky SL...
Page 57: ...SCHEMA ELETTRICO WIRING DIAGRAM MACCHINA MACHINE Snakky SL...
Page 58: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 59: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 60: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 61: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 62: ...by NECTA VENDING SOLUTIONS SpA NOTE...
Page 64: ......