cuiheat.com
126345-01D
18
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When
lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never
use tools. If the knob will not push in or turn by hand, don’t try
to repair it, call a qualified service technician or gas supplier.
Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
LIGHTING
INSTRUCTIONS
WARNING:
• If fireplace has glass doors, never operate this heater
with glass doors closed. If you operate heater with
doors closed, heat buildup inside fireplace will cause
glass to burst. Make sure there are no obstructions
across opening of fireplace.
• You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed before
running heater.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Orange
flame will also be present. Open damper or window
to vent smell. This will only last a few hours.
NOTE: Home owners generally prefer to operate their heater with
the chimney damper closed. This will put all the heat into the room.
However, there may be times you will desire the full flames of the
HI heat setting but will find the heat output excessive. You can open
the chimney damper (if you have one) fully or partially to release
some of the heat.
6. Place Right top log as shown in Figure 41. This log will fit on the
matching pins on rear bottom log and front bottom log.
NOTE:
this is the final assembly for the 24'' model
.
Figure 41 - Placing 24/30" Top Right Log
(Final Assembly for 24" Model)
Figure 42 - Placing 30" Top Middle Log
(Final Assembly for 30" Model)
Top Right Log
Pins for Top Front Log
30" Model Only
Top Front Log
30"
Model Only
7.
For 30'' models:
Place the top front log as shown in Figure 42.
This log will fit on the matching pins on on the middle, and front
logs.
NOTE:
this is the final assembly for the 30'' model
.
INSTALLATION
Continued