cuiheat.com
126345-01D
10
See chart for minimum permanent flue opening you must provide.
Attach damper clamp so the minimum permanent flue opening will
be maintained at all times.
INSTALLATION
Continued
Chimney
Height
Minimum Permanent
Flue Opening
6' to 15'
39 sq. in.
15' to 30'
29 sq. in.
Figure 9 - Attaching Damper Clamp
Manufactured Fireplace
Masonry Fireplace
Area of Various Standard Round Flues
Diameter
Area
5"
20 sq. in.
6"
29 sq. in.
7"
39 sq. in.
8"
51 sq. in.
Damper
Clamp
Damper
Clamp
Damper
Damper
Damper
INSTALLING HEATER BASE ASSEMBLY
WARNING: You must secure this heater to fire-
place floor. If not, heater will move when you adjust
controls. Moving heater may cause a gas leak or log
misplacement.
WARNING: If installing in a sunken fireplace,
special care is needed. You must raise the fireplace
floor to allow access to heater control panel. This will
ensure adequate air flow and guard against sooting
and controls being damaged. Raise fireplace floor
with noncombustible material. Make sure material
is secure.
CAUTION: Do not pick up heater base assembly
by burners. This could damage heater. Only handle
base assembly by grates.
IMPORTANT: Make sure the heater burners are level. If heater is not
level, heater will not work properly.
Installation Items Needed
• hardware package (provided with heater)
• approved flexible gas hose and fittings (if allowed by local codes)
(not provided)
• sealant (resistant to propane/LP gas, not provided)
• electric drill with 3/16" drill bit (metal or masonry as applicable)
• flathead screwdriver
• pipe wrench
1. Connect approved flexible gas hose to gas control fitting in heater
(see Figure 10).
IMPORTANT: Hold gas fitting with wrench when connecting flexible
gas hose.
2. Locate two masonry screws in hardware package.
3. Place heater base in fireplace.
4. Place logs in their proper position on heater base (see Installing
Logs, starting on Page 14).
5. Center heater base and logs front-to-back and side-to-side in
fireplace.
6. Carefully remove logs without moving heater base.
7. Mark screw locations through one hole on each side of the
mounting bracket (see Figure 11). If installing in a brick-bottom
fireplace, mark screw locations in mortar joint of bricks.
Figure 10 - Attaching Flexible Gas Hose to Heater
Flexible Gas Hose (if
allowed by local codes)
Fitting
8. Remove heater base from fireplace. If installing optional control
accessories, do so at this time. Follow all directions provided with
accessory.
9. Drill holes at marked locations using 3/16" drill bit.
10. Attach base assembly to fireplace floor using two masonry screws
(in hardware package).
Figure 11 - Attaching Base to Fireplace Floor
Masonry
Screw
Mounting
Bracket