WARNING: Damper handle will be hot if heater
has been running.
1. STOP! Read the safety information in the left column.
2. Make sure equipment shutoff valve is fully open.
3. If equipped with a remote control, set selector switch in the OFF
position.
WARNING: Burners will come on automatically
within one minute when the selector switch is in the
ON position after the pilot is lit.
4. Press in and turn control knob clockwise
to the OFF position
(see Figure 43).
5. Wait five (5) minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow “B” in
the safety information, Page 19. If you don’t smell gas, go to the
next step.
6. Press in and turn control knob counterclockwise
to the
PILOT position. Press in control knob for five (5) seconds (see
Figure 43).
NOTE: You may be running this heater for the first time after
hooking up to gas supply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will allow air to bleed
from the gas system.
7. With control knob pressed in, press and release Igniter button.
This will light pilot. The pilot is attached to the front burner. If
needed, keep pressing Igniter button until pilot lights.
NOTE: If pilot does not stay lit, contact a qualified service person
or gas supplier for repairs. Until repairs are made, light pilot with
match. To light pilot with match, see Manual Lighting Procedure.
8. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob.
• If control knob does not pop out when released, contact a quali-
fied service person or gas supplier for repairs.
NOTE: If pilot goes out, repeat steps 4 through 8.
OPERATION
Continued
Figure 43 - Control Knob and Igniter Button Location (Shown as
Supplied, No Control Options)
Figure 44 - Pilot (Propane/LP)
Figure 45 - Pilot (Natural)
Igniter
Electrode
Pilot Burner
Pilot Burner
Flame Adjustment Knob
Control
Knob
Igniter
Button
9. Slightly push in and turn control knob counterclockwise
to
the ON position.
10. Wait one minute and switch selector switch, if optional re-
mote control is used, to the ON position to light burners.
NOTE: AUTO is only functional when using optional accessories.
11. Set flame adjustment knob to any level between HI and LO.
12. To leave pilot lit and shut off burners only: turn control knob
clockwise
to the PILOT position, or use remote control
manual OFF button, or set selector switch in the OFF position.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
WARNING: If optional thermostat remote control is
used, make sure the selector switch is in the OFF posi-
tion when you are away from home for long periods of
time. Heater will come on automatically with selector
switch in the ON position.
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the OFF position.
2. If Using Optional Hand-Held Remote: Set selector switch in the
OFF position to prevent draining battery.
3. Close equipment shutoff valve (see Figure 14, Page 12).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions, Pages 18
and 19.
2. Depress control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob. Now follow steps 9