PARAGON960 x4 32CH
80
FTP Upload File Type:
Select MP4 file type to upload videos to FTP server; select JPEG file
type to upload snapshots to the FTP server.
Alarm Output:
Select an alarm output number. When an alarm is triggered, the signal will be
transmitted through the selected alarm output relay.
Output Type:
Select an output type when an alarm is triggered.
Timeout: Select this option and then set up the Timeout Duration in the field below, the
alarm output will last for the setup duration time (10 ~ 150 seconds).
Permanent: Alarm will remain active until the user presses the “Enter” key on the IR
Remote Control or resets the alarm remotely.
Transparent: Alarm output remains as long as the alarm input is active.
Trans + Timeout: Alarm output continues until event ends, then continues for the setup
duration time (10 ~ 150 seconds).
Timeout Duration:
This function only appears when you select
Timeout
or
Trans + Timeout
options in the Output Type drop-down list. Select a duration time for the motion event. The
alarm output will last for the setup duration time between 1 and 150 seconds.
Matrix:
Select the Matrix number which you want to configure.
Monitor:
Matrix monitor display options when an alarm event occurs.
No change: No change on the matrix monitor display.
Spot: A full screen of the event camera will display on the matrix monitor. If the sequence
function is on, the matrix monitor will display alarm image of the selected camera
according to the Output Type time and then return to sequence process.
Main Monitor:
Select
Full Screen
to force the camera associated with the selected alarm
number to display full screen on the Main Monitor. The full screen camera view will last
according to the Output Type selected in the field above.
Call Monitor:
Select
Full Screen
to force the camera associated with the selected alarm
number to display full screen on the Call Monitor. The full screen camera view will last
according to the Output Type selected in the field above.
Record:
Select a camera to start recording when the associated alarm number is triggered.
Input Type:
Select an input type when the selected alarm number is triggered. The options
include N.O. and N.C.
Active Camera:
This function is for associating an alarm trigger with a specific camera. For
example, if you set up an external motion detector near Camera 2, you can select Camera 2 in
this field. The alarm will be associated with this camera for full screen display, event logging
and PTZ actions.
PTZ:
If the Active Camera selected above is a PTZ camera, you can further set up the PTZ
actions in this field.
Apply To: