Installation (continued)
14
Step Three: Connect pump to battery or 12V supply
WARNING
Batteries are hazardous because they contain caustic acid, can emit explosive gases, and can
cause electric shock.
Caution must be exercised when making connections to a battery to avoid shock and contact with
the acid, and to prevent any sparking that could lead to an explosion.
ALWAYS follow the safety instructions and steps listed below i
n exact sequence
when
connecting the pump to the battery terminals.
1. Preparatory
safety
Preparatory safety steps:
ALWAYS use eye protection
NEVER smoke or work near sparks or other sources of ignition.
NEVER touch both battery terminals at the same time or with any
non-insulated tools.
If battery acid contacts skin or clothing, flush immediately with water
and neutralize with baking soda.
2. Electrical
requirements
The pump should be on a dedicated (individual) circuit, controlled
with a double pole switch (UL/CSA certified) rated at or above the
fuse ampere indicated by the pump motor label. Depending on
distance of the power source from the pump and ampere load on the
circuit, wire may need to be heavier than indicated by the chart.
The pump is
protected with a fuse
. Use an approved wire of the size
specified or heavier.
Voltage
Model
Fuse
(amp)
Wire Leads
Wire Size
(Stranded MTW)
12 VDC EFHP-2000
20.0
RED (po)
BLACK (negative -)
#12 AWG (4.0mm
2
)
(or heavier)
Note:
Use #10 AWG (5.0mm
2
) for wire lengths over 12 feet (3.6m). Do not
exceed 25 feet (7.6m) of total wire length.
A remote switch is included for temporarily shutting off the pump’s operation.
Call Everflo Product Support at 1-800-864-1649 to order replacement remote
switch Everflo Item #EF-794292.
3. Connect pump
to battery
Connect the pump to a 12V DC battery using the following procedure:
a)
Disconnect the vehicle battery ground wire.
b)
Connect the pump clamp with the
red
wire to the
positive (+)
terminal
of the battery.
c)
Connect the pump clamp with the
black
wire to the
negative (-)
terminal of the battery.
d)
Reconnect the vehicle battery ground wire.
Note:
Skip steps (a) and (d) if battery is not in a vehicle.
WARNING: