EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 40 of 66
d7
0
15
min
2
2
dripping duration (the compressor and the
evaporator fan remain off during dripping and
the defrosting output will be deactivated)
d15
0
99
min
0
0
minimum duration of compressor switch-on
on activation of defrosting so these can be
activated (only if parameter d1 is set at 1) (8)
d16
0
99
min
0
0
duration of pre-dripping (only if parameter d1
is set at 1; the compressor and evaporator
fan will be off during pre-dripping and the
defrosting output will remain activated)
Par.
Min.
Max.
Unit
EVXV802
EVXV812
EVXV805
EVXV815
Temperature alarms (9) (10)
A1
0.0
99.0
°C/°F (1)
10.0
10.0
cabinet
temperature
below
which
the
minimum temperature alarm is activated
(relative to the work set-point, i.e. “r10 - A1”
during post blast chilling storage and “r11 -
A1” during post deep freezing storage; (“
AL
”
code); also see parameter A11 (4)
A2
0
1
- - - -
1
1
enabling of minimum temperature alarm
(“
AL
” code)
1 = yes
A4
0.0
99.0
°C/°F (1)
10.0
10.0
cabinet
temperature
above
which
the
maximum temperature alarm is activated
(relative to the work set-point, i.e. “r10 +A4”
during post blast chilling storage and “r11
+A4” during post deep freezing storage;
(“
AH
” code); also see parameter A11 (4)
A5
0
1
- - - -
1
1
enabling of maximum temperature alarm
(“
AH
” code)
1 = yes
A7
0
240
min
15
15
temperature alarm delay (“
AL
” code and
“
AH
” code)