EVCO S.p.A.
EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 37 of 66
r20
0
1
- - - -
1
1
memorisation of the quick modification value
during the "On" status before starting the
operating cycle
0 = no (on start-up of the successive same
cycle, the values established with
parameters r7 and r3 or those
establishes with r4 and r8 will be re-
proposed)
1 = yes (on start-up of the successive
same cycle the rapidly modified values
will be re-proposed before starting the
previous same cycle)
r21
0
1
- - - -
1
1
modality the operating cycle is started time
controller rather than time controlled
0 = automatic
(or
through
the
test
regarding correct insertion of the
needle probe)
1 = by hand (or pressing and releasing the
BLAST CHILLING or DEEP FREEZING
key)
r22
0
1
- - - -
0
0
modality to start pre-cooling
0 = automatic (or pressing the BLAST
CHILLING key 1 s)
1 = both automatic (or passing from the
"stand-by" status to the "on", then
switching on the device) and by hand
(or pressing the BLAST CHILLING key
1 s)
r23
0
50
s
2
2
duration of the buzzer activation to signal the
verification test for the correct insertion of the
needle probe will not have been completed
successfully
Par.
Min.
Max.
Unit
EVXV802
EVXV812
EVXV805
EVXV815
Compressor protections
C0
0
240
min
0
0
minimum time between restoring the power
supply after a power cut, occurring during an
operating cycle and compressor switch-on
C1
0
240
min
5
5
minimum time between two consecutive
compressor switch-ons (3)
C2
0
240
min
3
3
minimum time between compressor switch-off
and successive switch-on (3)