5.8
Defrosting activation in manual mode
Operate as follows:
1.
Make sure the device is in the "on" status or a storage is in progress.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.1
In models EVXV802 and EVXV812, hold the UP key down for 4 s: the
LED will switch on.
3.2
In models EVXV805 and EVXV815, hold the DEFROSTING key down for 4 s: the
LED will switch on.
If the evaporator probe is enabled, i.e. the parameter P4 is set at 1 and on activation of defrosting the evaporator
temperature is above that established with parameter d2, defrosting will not be activated.
5.9
Switching the cabinet light on/off in manual mode (in
EVXV805 and EVXV815 models only)
Operate as follows:
1.
Make sure that parameter u11 is set at 0.
2.
Make sure no procedures are in progress
3.
Press and release the AUXILIARY key: the
AUX
LED will switch on/off.
5.10
Locking/unlocking the keyboard
Operate as follows to lock the keyboard:
1.
Make sure no procedures are in progress
2.
Hold the DOWN key and the START/STOP key down for 1 s: the display will show “
Loc
” for 1 s.
The following operations will not be allowed if the keyboard is locked:
-
switching the device on/off
-
cabinet temperature display (with the procedure given in paragraph 5.4)
-
display of the temperature detected by the needle probe (with the procedure given in paragraph 5.5)
-
evaporator temperature display
-
condenser temperature display
-
defrosting activation in manual mode
-
operating cycle start-up/cut-off
-
switching on UV light for sterilisation cycle
-
heating the needle probe
-
displaying information relative to the HACCP alarms
-
deleting the information relative to the HACCP alarms
-
displaying compressor operating hours
-
deleting the compressor operating hours
-
setting the real date and time.
Operate as follows to unlock the keyboard:
1.
Make sure no procedures are in progress
2.
Hold the DOWN key and the START/STOP key down for 1 s: the display will show “
UnL
” for 1 s.