EVCO S.p.A.
EVF 300 series | Installer manual ver. 1.3 | Code 144F300E134
Page 46 of 62
15
SIGNALS
15.1
Signals
The following table illustrates the meaning of the device LEDS.
LED
MEANING
"UPPER" display
if the parameter CFG is set at 0, chamber LED
if it is on, the top output and/or the floor output will be on
if it flashes, setting of the work set-point will be in progress (with the procedure illustrated in paragraph
14.2)
if the parameter CFG is set at 1, top LED
if it is on, the top output will be on
if it flashes, setting of the top set-point will be in progress (with the procedure illustrated in paragraph 14.3)
in the "LOWER"
display
floor LED
if it is on, the floor output will be on
if it flashes, setting of the floor set-point will be in progress (with the procedure illustrated in paragraph
14.3)
M:F
Multifunction LED
if it is on, the multifunction output will be on
Energy Saving LED
if on, the "energy saving" function is in progress
CYCLES
number of steam injections in cyclic mode LED
if it is on, the value shown in the floor part of the “LOWER” display will be the residual count of the number
of steam injections in cyclical mode and the activation mode of the steam injector will be “AUT
PERSISTENT MANUAL”
T
ON
switch-on duration of the steam injector LED
if it is on, the value shown in the floor part of the "LOWER" display will be the minimum duration of steam
injector switch-on and the activation mode of the steam injector will be " PERSISTENT MANUAL"
if it flashes, quick setting of the time tOn will be in progress (i.e. of the switch-on duration of the steam
injector, with the procedures illustrated in the chapter 7.1)
T
OFF
switch-off duration of the steam injector LED
if it flashes, quick setting of the time tOF will be in progress (i.e. of the switch-off duration of the steam
injector, with the procedures illustrated in the chapter 7.1)
In the "UPPER"
display
if the parameter CFG is set at 0, temperature associated to the chamber LED
if it is on, the value displayed in the top part of the display will be a temperature associated to the chamber
if it flashes, setting of the work set-point will be in progress (with the procedure illustrated in paragraph
14.2)
if the parameter CFG is set at 1, temperature associated to the top LED
if it is on, the value displayed in the top part of the display will be a temperature associated to the top
if it flashes, setting of the top set-point will be in progress (with the procedure illustrated in paragraph 14.3)