9
“PROGRAMS” FUNCTION
9.1
Preliminary notes
The "programs" function allows to memorise several settings
in a program; on program start-up the device will operate with
the settings memorised in the same.
Starting the program causes the cooking cycle to start;
interruption of the program causes the cooking cycle to be
interrupted.
If the CFG parameter is set at 0, the function will allow to
memorise the following settings in a program:
- work
set-point
-
power distributed at the top
-
power distributed at the floor
-
switch-on duration of the steam injector
-
switch-off duration of the steam injector
-
number of steam injections in cyclic mode
- cooking
timer.
If the CFG parameter is set at 1, the function will allow to
memorise the following settings in a program:
- top
set-point
- floor
set-point
-
switch-on duration of the steam injector
-
switch-off duration of the steam injector
-
number of steam injections in cyclic mode
- cooking
timer.
If a number of steam injections in cyclic mode is envisioned
among the settings memorised in the program and on
program start-up the generator is off, these will be switched
on and the method of consent on activation of the steam
injection will depend on parameter P4.
9.2
Memorisation of a program
Operate as follows to memorise a program:
1.
Make sure that the device is on, that a cooking
cycle is not in progress and no procedure is in
progress.
2.
Set the work set-point, the top set-point, the floor
set-point, the power distributed at the top and
that distributed at the floor with the procedures
illustrated in chapter 14 “CONFIGURATION”.
3.
Set the switch-on duration of the steam injector,
the switch-off duration of the steam injector and
the number of steam injections in cyclic mode with
the procedures illustrated in the 7.1 “Steam
injection” paragraph.
4.
Set the cooking timer with the procedure
illustrated in paragraph 8.2 “Setting the cooking
timer”.
5.
Hold the “PROGRAMS” key down for 1 s: the
bottom part of the “LOWER” display will show the
number of the first program not used; the
program number will flash.
Memorising a program
6.
Press and release the UP or DOWN key within 15 s
to set the number of the program.