Page 8/34
3.3
Charger installation on site
The structural engineering is to be performed according to the rules of art, including:
-
The concrete used must have a density of 350 kg/m
3
and should be frost proof.
-
The charger shall be secured to the ground and perfectly levelled.
o
Indeed, a tilt gap left/right or front/rear can damage the permeability of the product.
o
This will require setting the system level without ever using washers or other material that
does not guarantee continuous support between the base of the charger and the ground.
Reminder of the key data of the charger subsets:
-
The screen of the charger is located at a height of 125 cm.
-
The emergency stop button is located at a height of 104 cm.
-
The charging car connectors are located at a height of 118 cm.
-
These heights must be considered to avoid compromising the use of HMI from the charger in case
it is raised by a concrete foundation.
Note:
-
It is
recommended not to raise the charger more than 18 cm from the ground level where the user
will be positioned.
-
For the reasons above, we strongly recommend the use of our mounting kit.
3.3.1
Installation with Mounting kit (recommended option):
To ensure proper installation and therefore durability of our products, we recommend using the
clamping/sealing kit sold as an option with your charger.
The clamping/sealing kit comprises:
-
The upper sheet plate, raw aluminium, will remain on the surface (outside) 0,5 cm over the
concrete, acting as a guide for electrical conduit and charger support.
-
The lower sheet plate, galvanised, widely perforated for effective penetration into the concrete,
will be sealed in concrete as shown in the sealing insert.
-
10u x M12 nuts.
How to assemble:
1.
Screw one M12 nut from the upper end of each threaded rod.
2.
Mount the upper plate (alumimium).
3.
Screw one M12 nut on each threaded rod above the upper face of the upper plate.
4.
The distance between plates must be 4,5 cm.
5.
The distance from the upper plate (Al) to the upper end of the threaded rod must be 7,5 cm as a
maximum.
Summary of Contents for Troniq
Page 1: ...D000782AA6 EVBox Troniq Installation Manual ...
Page 27: ...Page 27 34 8 APPENDIX 3 DIMENSIONS Charger dimensions without Auxiliary power cabinet APC ...
Page 28: ...Page 28 34 Charger dimensions with Auxiliary power cabinet APC ...
Page 29: ...Page 29 34 9 APPENDIX 4 CONNECTION TERMINALS DETAILS POWER AND COMMUNICATION ...