Page 22/34
-
Opening/Closing:
- There are 3 Eastern EU locks on the left flank of the charger
- Open by
¼
left turn
- Close by
¼
right turn
5.2
Charger restart procedure without battery
The restart/commissioning procedure is as follows:
1.
Set the D3 circuit breaker to OFF, if applicable
2.
Wait 10 seconds
3.
Switch circuit breaker D7 to ON
4.
Switch circuit breaker D7’ to ON
5.
Switch circuit breaker D9 to ON
6.
Switch circuit breaker D3 to ON
7.
Finally switch circuit breaker D1 to ON
8.
You must close the door; there is no time limit for this
9.
Once the door is closed and locked, check that the side lights are green, and therefore indicate a
functional restart, otherwise repeat the procedure from step 1.