Pr48 = T seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
power outage duration
new status
switched off
any
switched off
ignition
< T
ignition
pellet loading without pre-load
< T
pellet loading
pellet loading with pre-load
any
switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning
< T
burn pot cleaning
switching off
< T
switching off
If the power outage duration is longer than T, the stove switches off.
10. ALARMS
In the event of a malfunction, the control board indicates the problem and activates various procedures depending on the type of alarm. The possible alarm
messages are listed below:
Display shows
No.
Cause
BLACK OUT
(1)
Absence of mains voltage
PROBE EXHAUST
(2)
Fume temperature probe fault
HOT EXHAUST
(3)
Fume overheating
FAN FAILURE
(4)
Exhaust blower fault, not working
NO LIGHTIN-
(5)
Stove does not ignite
NO PELLET
(6)
Shutting down due to insufficient pellets
SAFETY THERMAL
(7)
Safety thermostat activated
FAILURE DEPRESS
(8)
Depressor activated
TRIAC COC FAILURE
(AL B)
The auger tube turns continuously
PROBE WATER
(AL C)
Water probe broken or shorted
HOT WATER
(AL D)
Stove water maximum threshold exceeded
WATER PRESS ALARM
(AL E)
Water pressure too low or too high
In case of alarm, the stove is immediately switched off.
The alarm status can be reset by pressing the P4 button.
FUME TEMPERATURE PROBE ALARM
The alarm is triggered when the fume temperature probe is not working properly or is disconnected. The stove switches off when the alarm is active.
FUME TEMPERATURE OVER ALARM
This occurs if the fume probe detects a temperature greater than 280°C.
The stove switching-off phase starts immediately.
NON-IGNITION ALARM
The alarm is triggered whenever ignition fails. The shutdown procedure is immediately activated.
SWITCHING OFF ALARM DURING THE WORK PHASE
If during the work phase the flame goes out and the fume temperature drops below the minimum work threshold, the shutdown procedure is immediately activated.
AUGER SAFETY PRESSURE SWITCH ALARM
If the pressure switch detects a value below the trigger threshold, it immediately switches off the auger tube (to which it is connected in series) while the control
board acquires this change in status via the AL2 terminal in CN4.
FAILURE DEPRESS-
is displayed and the system is shut down.
GENERAL THERMOSTAT ALARM
If the general safety thermostat detects a value exceeding the trigger threshold, it immediately switches off the auger tube (to which it is connected in series), while
the control board acquires this change in status via the AL1 terminal in CN4. The message
SAFETY THERMAL
is displayed and the system is shut down. Unscrew
the black cap at the bottom of the cooking stove under the display and press the button to reset the contact.
FAULTY FUME INTAKE FAN ALARM
In the event that the fume fan fails, the stove stops and the
FAN FAILURE
message is displayed. The shutdown procedure is immediately activated.
SERVICE MESSAGE
The stove will display the message SERVICE (or SER) during operation depending on the number of hours of operation. The wording does not lock operation of
the stove, but non-routine maintenance will be required by an authorised technician, who will reset the service hours.
19