background image

05. COMPONENTS AND CONNECTIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES 

DELIVERY   

¾“ 

RETURN 

¾“ 

SYSTEM LOAD / DISCHARGE  

½" 

ELECTRONIC PUMP 

1” - 230 V 50 Hz 

BALL VALVE 

¾“ 

AUGER MOTOR  

5.3 RPM 

SPARK PLUG 

300 W  

PRESSURE TRANSDUCER 505 

3/8”  

SAFETY AND DISCHARGE VALVE 

3 BAR – ½” 

10 

EXPANSION TANK 

8 litres - 3/8” 

11 

OVEN BULK (IF ANY) 

25 W 

12 

OVEN HEATING ELEMENT (IF ANY) 

1200 W 

13 

OVEN PROBE 

NTC 

 

 

 

 

 

 

 

 

8

Summary of Contents for ISOTTA

Page 1: ...INSTRUCTION MANUAL PELLET HYDRO STOVES ISOTTA PELLET COOKING STOVE EN...

Page 2: ...ANCES p 5 04 3 SYSTEM CONNECTION AND DIAGRAMS p 6 05 COMPONENTS AND CONNECTIONS p 8 06 INSTALLATION p 10 06 1 HYDRAULIC CONNECTION p 10 07 METHOD OF USE p 11 07 1 HYDRO MODE p 11 07 2 OVEN MODE p 12 0...

Page 3: ...scita fumi C 119 71 173 89 Flue gas mass flow Flusso massico dei fumi g s 13 4 6 7 15 1 7 6 Efficiency Rendimento 93 5 95 5 89 0 93 5 Total heating output Potenza termica Kw 18 5 6 5 18 2 6 7 Water he...

Page 4: ...DISTANCES If the stove is to be installed in rooms where it is surrounded by combustible materials e g furniture wood cladding etc the following minimum clearances must be complied with Symbol mm Conv...

Page 5: ...m Convective air mm Isolating shim mm RECESSED INSTALLATION Rear wall under above hob Side wall under hob Floor Front Side hob irradiation area Above hob irradiation area C1 C2 B A D E 50 of which 50...

Page 6: ...04 3 SYSTEM CONNECTION AND DIAGRAMS 6...

Page 7: ...7...

Page 8: ...SCHARGE 4 ELECTRONIC PUMP 1 230 V 50 Hz 5 BALL VALVE 6 AUGER MOTOR 5 3 RPM 7 SPARK PLUG 300 W 8 PRESSURE TRANSDUCER 505 3 8 9 SAFETY AND DISCHARGE VALVE 3 BAR 10 EXPANSION TANK 8 litres 3 8 11 OVEN BU...

Page 9: ...NOTES 14 AUTOMATIC RELEASE VALVE 15 LCD DISPLAY 16 FIRE DOOR 17 OVEN DOOR 18 OVEN 19 OVEN ADJUSTMENT ON OFF B 20 HYDRO OVEN ADJUSTMENT A 9...

Page 10: ...draulic connections They are fixed with quick release clips The cooking stove is internally equipped with all the components for safety automatic vent valve 3 bar safety valve expansion tank stove saf...

Page 11: ...uld be positioned in this manner The lever of the Hydro Oven adjustment must be completely extracted while the Oven adjustment must be turned anti clockwise until it is completely positioned In this c...

Page 12: ...he Hydro Oven adjustment must be completely inserted while the Oven adjustment must be turned clockwise until it is completely positioned In this case the heat output of the stove is regulated accordi...

Page 13: ...SYMBOLS HYDRO OVEN adjustment OVEN adjustment CAUTION The HYDRO OVEN adjustment lever can be removed by unscrewing it OVEN HYDRO ADJUSTMENT COMPLETELY INSERTED ADJUSTMENT COMPLETELY EXTRACTED HYDRO AD...

Page 14: ...TON 3 P3 Set menu Use this button to access the temperature setting and user and technician parameter menu After entering the menu use this button to access the next sub menu or set the value and move...

Page 15: ...plays the temperature of the oven SET 08 3 MENU Press P3 Menu to access the menu It includes several items and levels to access settings and control board programming The menu items providing access t...

Page 16: ...hen stand by Below Water Set the stove comes on again and resumes operation The stove in no way considers the temperature measured by the ambient probe of the same stove WATER TAKES PRIORITY Mode 3 WI...

Page 17: ...d of the start up phase if no problems occurred the stove enters its normal working mode Changing set room temperature Press button P2 to change the set room temperature The display shows the current...

Page 18: ...seconds to switch off the stove The Auger tube stops immediately and the exhaust blower reaches its maximum speed value The CLEANING FINAL phase is performed Stove switched off The display will show t...

Page 19: ...itches off when the alarm is active FUME TEMPERATURE OVER ALARM This occurs if the fume probe detects a temperature greater than 280 C The stove switching off phase starts immediately NON IGNITION ALA...

Page 20: ...EMENT 95110021100 3 RELAY 951089800 4 OVEN CONTACT 5 505 PRESSURE TRANSDUCER CABLE 6 NTC TYPE OVEN PROBE 7 FUME MOTOR ENCODER 8 STOVE PROBE 9 ROOM PROBE 10 EXTERNAL THERMOSTAT 11 FUME PROBE 12 AUGER M...

Page 21: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Reviews: