Chapter 2 - PRE-INSTALLATION PLANNING
584S Frequency Inverter
2-13
584S Type 7
584S Type 7
584S Type 7
584S Type 7
Terminal
Terminal Description
M1/U, M2/V,
M3/W
Power outputs forming the 3-phase supply connection for the motor.
DC-
Power input/output. This terminal is used in conjunction with the DC+ terminal
when two or more controllers are coupled together. It carries a negative DC
link voltage.
DC+
Power input/output. This terminal is used in conjunction with the DC- terminal
only when two or more controllers are coupled together. It carries a positive
DC link voltage (typically 600V referred to terminal DC-).
DBR1
Power output. This terminal is used for connection to a braking resistor. Refer
to "DYNAMIC BRAKING
DYNAMIC BRAKING
DYNAMIC BRAKING
DYNAMIC BRAKING" for further details. This terminal is connected to the
negative side of the link capacitor when the brake option is not fitted.
DBR2
Power output. This terminal is used for connection to a braking resistor.
L1, L2, L3
Power inputs. These terminals are the 3-phase mains supply input, 380 - 460V
±
10% or 208 - 240V
±
10% AC line-to-line.
PE /
Power earth. This terminal must be connected to a permanent protective earth
(ground).
Motor earth connection. This terminal may be used for the protective earth
connection to the motor.
Table 2.4 - 584S ( TYPE 7 ) - Power Terminals
M3/W
M2/V
M1/U
L3
L2
L1
CONTROL PCB TERMINALS
DRB1
DC+
DRB2
DC-
PE
Figure 2.10 - 584S ( TYPE 7 ) - Power Terminals
This manual was downloaded on www.sdsdrives.com
+44 (0)117 938 1800 - [email protected]
Summary of Contents for 584S
Page 122: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Page 173: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Page 174: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...
Page 175: ...This manual was downloaded on www sdsdrives com 44 0 117 938 1800 info sdsdrives com ...