background image

18

JVF-M2 Series Outdoor Gas Fireplace  

              

                                                                                                                                                          

IGM2S-190417

TRIM and FINISH

INSTALLING THE FIRE MEDIA

 

The  

J Series Outdoor Gas Fireplace

 is shipped with fire media which is to be installed on top of the burner. 

Be certain that the fire media does not cover the pilot burner as well as no media is between the glass panels and 

burners to prevent glass breakage. Extra fire media can be ordered to cover the frosted glass.

The Fire Media

The fire media should be distributed evenly across the entire burner top. 

These fire media are available for the  

J Series Outdoor Gas Fireplace: (continued on next page)

The fire media must be installed according to these instructions. This fireplace must use only the type and 

amount fire media specified by European Home. An excessive amount of fire media may adversely affect 

the performance of the fireplace.

WARNING: All previously applied loose material must be removed prior to reapplication.

Pacific Fireglass

Clear Fireglass

Black Fireglass

Amber Fireglass

Summary of Contents for J series

Page 1: ...G If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment INSTALLER Leave t...

Page 2: ...ant Safety Information About Propane 4 Specifications and Dimensions 5 Clearances 9 Installation 10 Electric Installation 11 Gas Installation 13 Enclosing the Fireplace 15 Framing 16 Trim and Finish 17 Operating the Fireplace 20 Maintenance 22 Installation Record 24 Warranty 25 Appendix A LP Installation 26 ...

Page 3: ...aterials should not be hung from the appliance or placed on or near the appliance Anyguardorotherprotectivedeviceremovedforservicingtheapplianceshallbereplacedpriortooperating the appliance Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required as ne...

Page 4: ...verfilling prevention device and 3 provided with a cylinder connection device compatible with the connection for the appliance 4 If LP is hard plumbed to the fireplace the propane storage tank must have a pressure regulator set for 11 w c 2 74 kPa If a propane hose is used to connect a propane cylinder to the fireplace the following is required Inspect the hose before each use of the fireplace The...

Page 5: ...hr 49 901 48 308 Maximum Supply Pressure in w c 7 0 11 0 kPa 1 74 2 74 Manifold Pressure Maximum in w c 5 5 10 25 kPa 1 37 2 55 Manifold Pressure Minimum in w c 3 5 6 0 kPa 0 87 1 5 Electrical Rating V AC 120 Frosted Glass Stainless Steel Wall Panels x2 Glass Capture Panel x2 8 32 Pan Head Screw x2 Wind Guard Single Sided Only Left Bracket Right Bracket FIGURE 1 Clear Glass x2 x1 Single Side x2 Se...

Page 6: ...mm B viewable width 60 1524 mm C burner length 491 4 1251 mm D viewable height 171 2 444 mm E base to opening 71 2 190 mm F overall depth 18 457 mm G overall height 28 711 mm overall width does NOT include the nailing flanges B A C D E F G FIGURE 2 JVF M2 60 S FIGURE 3 JVF M2 60 ST A F B C D E G UNIT WEIGHT Pounds Kilograms 180 81 6 ...

Page 7: ...stible wall 0 0 Side of fireplace to side wall 0 0 Side of fireplace opening to combustible trim 4 5 Fireplace opening to side wall in front of fireplace 5 5 Top of fireplace opening to combustible mantel 17 0 Front of fireplace to back combustible wall 18 0 Maximum depth of mantel 12 0 JM2LL01180913 Model JVF 60 M2 ST JVF 60 M2 S Orifice Size NG 2x 39 DMS Orifice Size LP 2x 0 064 Gas Control Copr...

Page 8: ... any other material that can catch fire and burn is considered combustible Even though these materials may have been flame proofed made fire resistant or are fire rated they are considered combustible Standard and Type X drywall are both combustible NON COMBUSTIBLE MATERIALS A material is non combustible when it cannot catch fire and burn For example materials made of stone brick concrete tile ste...

Page 9: ... 4 5 114 mm D Fireplace opening to side wall in front of fireplace 5 5 140 mm E Side of fireplace to combustible side wall 0 0 mm F Top of fireplace opening to combustibles 6 153 mm G Top of fireplace opening to combustible mantel 17 432 mm Maximum depth of mantel 12 305 mm CLEARANCES TO COMBUSTIBLES FIGURE 5 Clearances Front Elevation View MANTEL SIDEWALL TRIM A B C D E F G FIGURE 6 Clearances Pl...

Page 10: ...nd may cause a flame outage and or excessive sooting If enclosed or sheltered the enclosure must be a an enclosure with walls on all sides but NO overhead cover or b a partial enclosure that includes an overhead cover but NO MORE THAN TWO side walls or c a partial enclosure that includes an overhead cover and three side walls as long as 30 percent or more of the horizontal periphery of the enclosu...

Page 11: ...errors can cause improper and dangerous operation This appliance must be electrically grounded in accordance with local codes or in the absence of local codes with either the National Electrical Code ANSI NFPA 70 for installations in the U S or the Canadian Electrical Code CSA C22 1 for installations in Canada Electrical work should only be performed by a qualified licensed electrician Electric po...

Page 12: ...s Outdoor Gas Fireplace IGM2S 190417 ELECTRIC INSTALLATION Power Supply Control Module LED Strip Antenna 120V AC Outlet LED LIGHT SCHEMATIC VLM60W 12 FIGURE 11 J M2 LED Lighting Schematic Diagram ELECTRIC INSTALLATION ...

Page 13: ...plicable The fireplace and its individual shutoff valve must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Note INSTALL THE NATURAL GAS SUPPLY The natural gas supply piping must have a separate gas shutoff valve and a capped 1 8 pipe tap...

Page 14: ... provided at floor level of the enclosure and must have a total free area of not less than 1 2 in2 lb 7 1 cm2 kg of stored fuel capacity If ventilation openings at floor level are in a sidewall there must be at least two openings The bottom of the openings must be 1 25 4 mm or less from the floor level and the upper edge no more than 5 127 mm above the floor level The openings must be equally size...

Page 15: ...he air outlet opening must be covered with a grill that has a free area of at least 36 in2 233 cm2 The grill opening should be small enough to prevent bugs mice and other pests from accessing the enclosure When choosing a grill give consideration to its rain and or weather resistance to ensure that as little weather gets inside the enclosure as possible A small hood at the top of the grill is reco...

Page 16: ... A Width 693 4 1772 mm 693 4 1772 mm B Height 32 813 mm 32 813 mm C Depth 18 457 mm 18 457 mm Accumulated rain water will drain from a 7 8 22 3mm opening in the center rear of the fireplace bottom This opening must not be blocked see Figures 19 20 for drain placement The water which runs through this opening will accumulate in the base of your enclosure and must be allowed to drain away from the e...

Page 17: ...or panels to cover light Make sure the clear glass is centered on the LED lights Clear glass must be used After the clear glass has been laid down install the frosted glass which should lie parallel to the burners covering the lights to hide them INSTALLING THE GLASS CAPTURE PANELS After the installation of the frosted glass panels install the glass capture panels between the end of the burner and...

Page 18: ...r the frosted glass The Fire Media The fire media should be distributed evenly across the entire burner top These fire media are available for the J Series Outdoor Gas Fireplace continued on next page The fire media must be installed according to these instructions This fireplace must use only the type and amount fire media specified by European Home An excessive amount of fire media may adversely...

Page 19: ...19 JVF M2 Series Outdoor Gas Fireplace IGM2S 190417 TRIM and FINISH Colbalt Fireglass Carrara Pebbles Beach Stones with Driftwood Beach Stones ...

Page 20: ...me height will be same level of last setting 1 On the remote control press and release the ON button Sparking will occur 8 seconds after ON button is pressed 2 Flames are automatically set to high Press the LOW button on the remote control to set the flames to low 3 When the flames are at the low setting press the HI button on the remote control to set the flames to high OPERATING INSTRUCTIONS USI...

Page 21: ...IREPLACE USING THE LED LIGHT REMOTE The LED remote control comes with a battery installed When using the LED remote control point the remote at the control side of the fireplace The eye which receives the signal is located on the control side of the fireplace FIGURE 21 ...

Page 22: ...ith a vacuum cleaner Cleaning the Stainless Steel 1 With all parts of the fireplace at room temperature use a high quality stainless steel cleaner to clean Be sure to softly clean WITH the grain Cleaning the Cabinet 1 Ensure that the space beneath the glass panels is kept free of dirt and debris Clean this area with a vacuum cleaner while being careful to not disturb any of the wiring or tubing 2 ...

Page 23: ...eces JVF GLASS ST CLEAR Control Module Repl JVF GS CM 01 Frosted Glass 60 S only 2 Pieces JVF GLASS S FROST Frosted Glass 60 ST only 2 Pieces JVF GLASS ST FROST Gas Valve Repl JVF GS GV M2 01 LED Light Bar 2 Pieces LED Light System Kit Repl JVF ES LED Momentary Contact Switch Repl JVF ES MCS 01 Pilot assembly Repl JVF GS PS M2 01 Remote Control Repl JVF GS RC 01 Rocker Switch Repl JVF ES RS 01 The...

Page 24: ...E INSTALLED ______________________________________ FUEL ______________________________________ MEASURED AFTER INSTALLATION INLET PRESSURE ______________________________________ MANIFOLD PRESSURE ______________________________________ INSTALLER Please complete and retain the installer Record below INSTALLER RECORD MODEL ______________________________________ DATE of PURCHASE _______________________...

Page 25: ...nt product part assumes the remaining warranty of the original product or ninety 90 days from the date of replacement or repair whichever provides longer coverage for you When a product or part is exchanged any replacement item becomes your property and the replaced item becomes the property of European Home All warranty claims must be submitted through the dealer from which you purchased the prod...

Page 26: ...ied in the manufacturer s instructions supplied with the kit This kit is to be used to convert the J M2 models from natural gas to propane It is not to be used to convert any other models The conversion must be performed only by a qualified service person or agency If the fireplace or burner has been connected to natural gas contact your local gas supplier to have the natural gas supply disconnect...

Page 27: ...t light at silver connector to remove light on single side both on see through Store in safe place 6 Remove 3 screws holding light reflector under where zip ties were with a 5 16 wrench Lift out and store 7 Remove 3 screws holding in rear reflector with 5 16 wrench lift out and store safely 10 Remove four 3 8 nuts and two 8 screws from the burners with a 3 8 and 5 16 wrench respectively and remove...

Page 28: ...ghten the connection When there are no leaks at the valve inlet light the burner and apply the leak test solution to the orifice fittings and the corrugated manifold tube 20 Fill out the information on the conversion label and attach it to the burner base to the right of the control panel Reattach the burner to the bottom of the case 21 Connect the Regulator Hose to the propane cylinder and verify...

Page 29: ...29 JVF M2 Series Outdoor Gas Fireplace IGM2S 190417 APPENDIX A NOTES ...

Page 30: ...linder Enclosure 14 I INSTALLATION 10 16 Dimensions 16 Electric 11 Fire Media 18 19 Framing 16 Gas 13 Installation Record 24 Locating the Fireplace 10 Rough Opening 16 Sheltered Enclosed 10 L LED 21 Operating 20 LISTING LABEL 7 LP Enclosure 14 Pressures 5 Safety 4 M MAINTENANCE 22 23 Burner 22 Cleaning 22 Fire Media 22 LED Lights 22 Pilot 22 Replacement Parts 23 N NATURAL GAS Installation 13 Press...

Page 31: ...ries Outdoor Gas Fireplace IGM2S 190417 EUROPEAN HOME a division of Europa Ja Inc 30 Log Bridge Road Building 300 Suite 303 Middleton MA 01949 www europeanhome com Designed and manufactured in the United States by ...

Reviews: