JVF-M2 Series Outdoor Gas Fireplace
IGM2S-190417
ELECTRIC INSTALLATION
The J-M2 fireplace must be wired to a GFCI protected 120V AC circuit using a waterproof connector. The
weatherproof control box is attached to a 65 inch long power cable on the left side of the fireplace.
FIGURE 10: J-M2 Gas Control Schematic Diagram
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
This appliance must be electrically grounded in accordance with local codes, or, in the absence of local
codes, with either the National Electrical Code ANSI/NFPA 70, for installations in the U.S. or the Canadian
Electrical Code, CSA C22. 1 for installations in Canada.
Electrical work should only be performed by a qualified, licensed electrician. Electric power must be off
when making connections or performing any service.
All wiring shall be in compliance with all local, city, and state codes.
Verify proper operation after servicing.