TC- and SW-cable reversed.
Check cable connection between receiver
and interrupter block.
Magnet unit not operating properly.
Replace gas valve.
Short between interrupter and SW cable.
Check interrupter block connection.
No gas (magnet unit drops after 30 second
audible count.)
Check gas supply.
Spark not lighting the pilot.
Check spark is crossing pilot orifice.
4.
Pilot lit.
No
Yes
FUNCTION
POSSIBLE CAUSE
REMEDY
Short between interrupter and
TC-cable.
Check connection to interrupter block.
Electronic measuring amplifier
defective.
Replace the receiver.
5.
Sparking stops after
pilot is lit.
No
6.
Motor turns to main gas
and pilot stays lit.
Magnet
unit
drops
(audible
sound)
No
Manual knob is in the “MAN” position.
Turn the control knob to “ON” position (posi-
tive latch is required.)
No
7.
Main burner is lit.
8.
Main burner stays lit.
No
Too much draft at pilot flame (poor
flame impingement of thermocouple.)
Check installation.
9.
Magnet unit drops while
motor turns. 3 beeps.
Yes
Receiver batteries low.
Replace transmitter batteries. Quality 1.5V
AA alkaline recommended.
Yes
Yes
Yes
Yes
No
Resistance in thermocouple circuit too high.
Check thermocouple circuit.
Not enough heat on thermocouple.
Check position of pilot to thermocouple
and intensity of pilot flame.
Low voltage from thermocouple.
Replace thermocouple. Do not over
tighten - hand tight + 1/4 turn maximum.
No gas (magnet unit drops after 30 second
audible count.)
Check gas supply.
Ignition sequence stops.
No reaction to transmitter command.
Reset system.
Add ground wire between pilot burner
and gas valve.
Do not coil the ignition cable.
Shorten the ignition cable, if possible.
Broken receiver
Ensure powered/unpowered receiver
allows manual operation.
No