OPERATING the BURNER
G Series
Linear Hearth Burner
European
Home
.com
23
Setting °C/24 Hour or °F/12 Hour Clock.
Press
OFF
and
SMALL FLAME
to toggle between °F/12 hr and °C/24 hr clock.
Setting the Time.
Simultaneously press the
SMALL FLAME
and
LARGE FLAME
buttons, the display now flashes.
Press
LARGE FLAME
to set the hour and
SMALL FLAME
to set the minute.
Press
OFF
to return to manual mode.
Changing the Mode of Operation.
Briefly pressing the
SET
button changes the mode of operation in the following order:
Man
-
Temp
-
Temp
-
Timer
- back to
Man
Man - Manual Flame Height Adjustment.
You are now able to use the remote control. To increase the flame, the
LARGE FLAME
button should be
depressed. Pressing the
SMALL FLAME
button on the handset will reduce the flame. The main flame may
be lowered all the way down until it is off, leaving only the pilot ignited.
Fully Extinguishing the Appliance.
From any heat setting, press the
OFF
button for a few seconds. This will cause the burner to fully extinguish.
The system has a safety interlock which will not allow the ignition until the interlock rests. This may take a
few minutes.
The appliance should be shut off completely using the
OFF
button on the handset and not left on pilot
only, except for temporary use. This resets the system and all safety features.
Temp - Daytime Temperature Mode.
The appliance must be in standby mode; pilot ignited. The room temperature is measured and compared to
the set temperature. The flame height is then automatically adjusted (up or down) to reach the daytime set
temperature.
Temp - Nighttime Setback Temperature Mode.
The appliance must be in standby mode; pilot ignited. The room temperature is measured and compared
to the nighttime setback temperature. The flame height is then automatically adjusted (up or down) to
achieve the nighttime setback temperature.
Timer Mode.
The appliance must be in standby mode; pilot ignited. The Timer setting allows you to set two burner
Temp
times and two burner
Temp
times every 24 hrs.
For
Temp
to operate as a thermostat, TEMP must be set at 4°C/40°F or higher.
If the
Temp
setting is decreased to - -, the motor will turn the valve to the standby position in the
times
and await the next burner
Temp
cycle.
USING THE REMOTE CONTROL ELECTRONIC IGNITION SYSTEM