Atop Industrial Managed Ethernet Switch
EH7510
User Manual V 1.0
45
Table 2.24
Label
Description
Factory Default
Community
Strings
Define name of strings.
Max. 15 Characters.
Public
(read-all-ony)
Private
(read-write-all)
Type
Choose from read-sysinfo-only, read-all-only,
and read-write-all. See notes below for a
detailed explanation.
-
*NOTE:
Read-sysinfo-only:
permission to read OID 1.3.6.1.2.1.1 Sub Tree.
Read-all-only:
permission to read OID 1 Sub Tree.
Read-write-all:
permission to read/write OID 1 Sub Tree.
2.9.2 Trap Receivers
EH7510 provides a trap function that allows an SNMP agent to notify the network
management system in case of a significant event, this allows users to configure SNMP
Trap setting, Fig. 2.39.b.
Fig. 2.39.b
*
Trap Receiver Example
*
Table 2.25
Label
Description
Factory Default
IP address
IP address of your Trap Server
NULL
Port
Trap Server service port.
162
Community
String
Community string for authentication.
Max. 15 characters.
NULL
2.9.3 SNMPv3 Users
SNMP V3 is an even securer protocol; users will be able to set a password and an
encryption key to enhance data security.
When choosing this option users can configure SNMP V3. EH7510 use MD5 (Message-
Digest algorithm 5) for authentication password, and DES (Data Encryption Standard) for
data encryption, Fig. 2.39.a.