18
-
Place the magnetic drilling machine on the workpiece in the desired position, and make sure
both magnet arrays are positioned correctly and the machine is in a stable position
-
Rotate the ratcheting action handles:
o
For precise positioning: partly (around 90°) clockwise, this allows for some
manoeuvrability
o
For drilling: 180° clockwise, with narrow part of both ratcheting action handles
pointing to the marking “FULL”
[image 4-5]
-
If you are not able to rotate the handles to “FULL” position easily and fully, not enough
magnet force is generated and the machine is unsafe to use. Check above mentioned
possible factors and fix the cause of insufficient magnetic force before proceeding.
The two handles on the Magswitch arrays need to be rotated the full 180 degrees to be
considered fully ON or OFF
-
Connect the machine to the air supply
Deactivating the magnets
To deactivate the magnets:
-
Gently press the release lever beneath the ratcheting action handle about 1.5 cm (9/16”)
towards the machine body to release the ratcheting action handles
[image 4-6]
Summary of Contents for TUBE.55/AIR
Page 28: ...28 8 Exploded views spare parts list 8 1 Exploded views ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 31: ...31 ...