143
4.1. Environmental Conditions
Storage and operating conditions specification of standard climatic class products
Storage Conditions
Applies to
1
Parameter
Conditions
Min
Max
Units
Ambient air temperature
-20 [-4] 70 [158] °C [°F]
Ambient air humidity
Non-condensing
10
90
% RH
Operating Conditions
Applies to
2
Parameter
Conditions
Min
Max
Units
FPGA die temperature
80 [176] °C [°F]
Ambient air temperature
0 [32] 55 [131] °C [°F]
Ambient air humidity
Non-condensing
10
90
% RH
Applies to
3
Parameter
Conditions
Min
Max
Units
FPGA die temperature
95 [203] °C [°F]
Ambient air temperature
0 [32] 55 [131] °C [°F]
Ambient air humidity
Non-condensing
10
90
% RH
1
1629 Coaxlink Duo PCIe/104-EMB
,
1630 Coaxlink Mono
,
1631 Coaxlink Duo
,
1632 Coaxlink Quad
,
1633 Coaxlink
Quad G3
,
1633-LH Coaxlink Quad G3 LH
,
1635 Coaxlink Quad G3 DF
,
1637 Coaxlink Quad 3D-LLE
,
3602 Coaxlink
Octo
,
3603 Coaxlink Quad CXP-12
,
3603-4 Coaxlink Quad CXP-12
,
3620 Coaxlink Quad CXP-12 JPEG
,
3620-4
Coaxlink Quad CXP-12 JPEG
,
3621 Coaxlink Mono CXP-12
,
3621-LH Coaxlink Mono CXP-12 LH
,
3622 Coaxlink Duo
CXP-12
,
3622-LH Coaxlink Duo CXP-12 LH
and
3625 Coaxlink QSFP+
.
2
1629 Coaxlink Duo PCIe/104-EMB
,
1630 Coaxlink Mono
,
1631 Coaxlink Duo
,
1632 Coaxlink Quad
,
1633 Coaxlink
Quad G3
,
1635 Coaxlink Quad G3 DF
,
1637 Coaxlink Quad 3D-LLE
and
3625 Coaxlink QSFP+
.
3
3602 Coaxlink Octo
,
3603 Coaxlink Quad CXP-12
,
3603-4 Coaxlink Quad CXP-12
,
3620 Coaxlink Quad CXP-12
JPEG
,
3620-4 Coaxlink Quad CXP-12 JPEG
,
3621 Coaxlink Mono CXP-12
and
3622 Coaxlink Duo CXP-12
.
eGrabber
Hardware Manual