181
I/O configuration capabilities and constraints
Group
Single-ended I/O
I/O#
Input
Output
Group #1
MIO1
MIO3
2 x TTL in
2 x 5 V CMOS out
Group #2
MIO5
MIO7
2 x TTL in
2 x 5 V CMOS out
Group #3
MIO9
MIO11
2 x TTL in
2 x 5 V CMOS out
Group #4
MIO13
MIO15
2 x TTL in
2 x 5 V CMOS out
Group #5
MIO17
MIO19
2 x TTL in
2 x 5 V CMOS out
Group #6
MIO21
MIO23
2 x TTL in
2 x 5 V CMOS out
Group #7
MIO25
MIO27
2 x TTL in
2 x 5 V CMOS out
Group #8
MIO29
MIO31
2 x TTL in
2 x 5 V CMOS out
Group #9
MIO33
MIO34
MIO35
MIO36
4 x TTL in
4 x 5 V CMOS out
Group #10
MIO37
MIO38
MIO39
MIO40
4 x TTL in
4 x 5 V CMOS out
The 24 I/O ports are configurable by group. There are 10 groups:
□
The groups #1 to #8 contain
2 single-ended I/O ports
.
□
The groups #9 and #10 contain
4 single-ended I/O ports
.
Within a group, it is allowed to set
all
the I/O ports:
□
for TTL input operation
OR
...
□
for 5 V CMOS output operation.
TIP
The configuration is saved into a non-volatile memory on the I/O module.
The configuration is automatically restored after applying power.
eGrabber