30
The heartbeat detection defaults to be off. The parameters that can be enabled are given in the table below:
Item
Parameters
Application and specification
Send mode
UDP,
TCP/IP
It defaults to use UDP.
Heartbeat interval
10s,
30s,
60s,
120s,
300s
Set up the time for heartbeat detection according to
the significance of the device installation scenes.
Host machine
address
IP address of the host machine on which the status
server in the management center platform is.
Host port
5050
Fill in based on facts.
5.3. Recording Parameters
In the menu for recording parameters, it is able to set up the recording parameters, like storage plan timetable,
FTP save and picture snapshot, etc.
5.3.1. FTP Parameters
Click “FTP Set” to set up the parameters like FTP server and recording timetable, etc.
It is required to set up the address, port, logon username, and password of FTP server. The data include
storage time and storage path, etc.
Fig. 59.
Item
Parameters
Application and specification
FTP server
Address, port, username,
password
Fill in according to the settings of FTP servers
Data package
time
1 – 60min
It is suggested to make a package every 5 minutes.
Storage path
Custom defined
If using a custom-defined storage path, the user can
specify a path for storage on FTP server.
Storage mode
Schedule and Schedule
Always: 24hrs continuous recording.
Schedule: recording by time-phased
Storage con
-
tent
Start record second stream After checking, it will store the second stream
Time Schedule Monday – Sunday
Four different time segments can be set for each day, or be the
same by copy.